![YOKOGAWA FLXA21 User Manual Download Page 52](http://html.mh-extra.com/html/yokogawa/flxa21/flxa21_user-manual_911262052.webp)
<6. Function block parameters and Methods>
6-26
IM 12A01A02-72E
3rd Edition : Oct. 01, 2015-00
Alarm / Status
TB .status
pH1
Temperature1
ORP1
rH1
Ref.
impedance1
Empty
Checksum error
in SENCOM
(Setting data)
Fault BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-
Configuration
Error
EEPROM error
in SENCOM
Fault BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
SENCOM
comm. error
Fault BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
Checksum error Fault BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
Sensor type not
correct
Fault BAD-
Configuration
Error
BAD-
Configuration
Error
BAD-
Configuration
Error
BAD-
Configuration
Error
BAD-
Configuration
Error
Internal error in
SENCOM
Fault BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
SENCOM not
connected
Fault BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
BAD-Sensor
Failure
EEPROM error
Fault BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
Sens. mod. not
work
Fault BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
BAD-Device
Failure
Logbook
(almost) full
Warning
—
—
—
—
—
Wash response
time failure
Warning
—
—
—
—
—
Calibration Due
Warning
UNCERTAIN-
Nonspecific
—
UNCERTAIN-
Nonspecific
UNCERTAIN-
Nonspecific
—
pH too high
Warning
UNCERTAIN-
sensor
conversion
not accurate
—
—
UNCERTAIN-
sensor
conversion
not accurate
—
pH too low
Warning
UNCERTAIN-
sensor
conversion
not accurate
—
—
UNCERTAIN-
sensor
conversion
not accurate
—
Temperature too
high
Warning
UNCERTAIN-
sensor
conversion
not accurate
UNCERTAIN-
sensor
conversion
not accurate
—
UNCERTAIN-
sensor
conversion
not accurate
—
Temperature too
low
Warning
UNCERTAIN-
sensor
conversion
not accurate
UNCERTAIN-
sensor
conversion
not accurate
—
UNCERTAIN-
sensor
conversion
not accurate
—
Temp. comp.
error(pH)
Warning
UNCERTAIN-
Nonspecific
—
—
UNCERTAIN-
Nonspecific
—
ORP too high
Warning
—
—
UNCERTAIN-
sensor
conversion
not accurate
—
—
ORP too low
Warning
—
—
UNCERTAIN-
sensor
conversion
not accurate
—
—
rH too high
Warning
—
—
—
UNCERTAIN-
sensor
conversion
not accurate
—
rH too low
Warning
—
—
—
UNCERTAIN-
sensor
conversion
not accurate
—
Impedance 1 too
high
Warning
UNCERTAIN-
sensor
conversion
not accurate
—
UNCERTAIN-
sensor
conversion
not accurate
UNCERTAIN-
sensor
conversion
not accurate
—
Impedance 1 too
low
Warning
UNCERTAIN-
sensor
conversion
not accurate
—
UNCERTAIN-
sensor
conversion
not accurate
UNCERTAIN-
sensor
conversion
not accurate
—