78
94 CONC_TABLE_
CONDUCTIVITY_1
O/S
NOT A
NUMBER
Conductivity 1 in the additional concentration table.
79
95 CONC_TABLE_
CONDUCTIVITY_2
O/S
NOT A
NUMBER
Conductivity 2 in the additional concentration table.
80
96 CONC_TABLE_
CONDUCTIVITY_3
O/S
NOT A
NUMBER
Conductivity 3 in the additional concentration table.
81
97 CONC_TABLE_
CONDUCTIVITY_4
O/S
NOT A
NUMBER
Conductivity 4 in the additional concentration table.
82
98 CONC_TABLE_
CONDUCTIVITY_5
O/S
NOT A
NUMBER
Conductivity 5 in the additional concentration table.
83
99 CONC_TABLE_
CONDUCTIVITY_6
O/S
NOT A
NUMBER
Conductivity 6 in the additional concentration table.
84
100 CONC_TABLE_
CONDUCTIVITY_7
O/S
NOT A
NUMBER
Conductivity 7 in the additional concentration table.
85
101 CONC_TABLE_
CONDUCTIVITY_8
O/S
NOT A
NUMBER
Conductivity 8 in the additional concentration table.
86
102 CONC_TABLE_
CONDUCTIVITY_9
O/S
NOT A
NUMBER
Conductivity 9 in the additional concentration table.
87
103 CONC_TABLE_
CONDUCTIVITY_10
O/S
NOT A
NUMBER
Conductivity 10 in the additional concentration
table.
88
104 CONC_TABLE_
CONDUCTIVITY_11
O/S
NOT A
NUMBER
Conductivity 11 in the additional concentration
table.
89
105 CONC_TABLE_
CONDUCTIVITY_12
O/S
NOT A
NUMBER
Conductivity 12 in the additional concentration
table.
90
106 CONC_TABLE_
CONDUCTIVITY_13
O/S
NOT A
NUMBER
Conductivity 13 in the additional concentration
table.
91
107 CONC_TABLE_
CONDUCTIVITY_14
O/S
NOT A
NUMBER
Conductivity 14 in the additional concentration
table.
92
108 CONC_TABLE_
CONDUCTIVITY_15
O/S
NOT A
NUMBER
Conductivity 15 in the additional concentration
table.
93
109 CONC_TABLE_
CONDUCTIVITY_16
O/S
NOT A
NUMBER
Conductivity 16 in the additional concentration
table.
94
110 CONC_TABLE_
CONDUCTIVITY_17
O/S
NOT A
NUMBER
Conductivity 17 in the additional concentration
table.
95
111 CONC_TABLE_
CONDUCTIVITY_18
O/S
NOT A
NUMBER
Conductivity 18 in the additional concentration
table.
96
112 CONC_TABLE_
CONDUCTIVITY_19
O/S
NOT A
NUMBER
Conductivity 19 in the additional concentration
table.
97
113 CONC_TABLE_
CONDUCTIVITY_20
O/S
NOT A
NUMBER
Conductivity 20 in the additional concentration
table.
98
114 CONC_TABLE_
CONDUCTIVITY_21
O/S
NOT A
NUMBER
Conductivity 21 in the additional concentration
table.
99
115 POLARIZATION
RO
—
Degree of polarization of the sensor.
100
116 SENSOR_OHMS
RO
—
Non-compensated resistance of the sensor.
101
117 USP
RO
—
Margin of safety for the water for injection defined
by USP<645>.
102
118 DETC_
WELLNESS_
POLARIZATION
RO
—
Sensor wellness indicator by Polarization.
103
119 DETC_
WELLNESS_
CELL_CONST
RO
—
Sensor wellness indicator by Cell Constant.
104
120 DETC_
WELLNESS_
HEAT_CYCLE
RO
—
Sensor wellness indicator by heat cycle.
105
121 DETC_
WELLNESS_
PROG_TIME
RO
—
Sensor wellness indicator by elapsed time.
106
122 MODULE_PDN
RO
Production no. Product number of Sensor module.
107
123 MODULE_
SOFTREV
—
"Rn.nn"
Software revision of Sensor module.
108
124 HOUSING_PDN
RO
Production no. Product number of Housing module.
109
125 HOUSING_
SOFTREV
—
“Rn.nn”
Software revision of Housing module.
110
126 ERR_CONFIG_
COND_OR_
CONC_TOO_
HIGH
O/S
Warning