36
IM 701450-61E
Command
Function
Page
MEASure Group
:MEASure:CHANnel<x>:{<Parameter>}:{COUNt|SDEViation|MAXimum|MEAN|MINimum}?
Queries the statistical value of the power analysis parameter.
45
:MEASure:CHANnel<x>:{<Parameter>}:STATe
Turns ON/OFF the power analysis parameter or queries the current setting.
45
:MEASure:CHANnel<x>:{<Parameter>}:VALue?
Queries the value resulting from the automated measurement of the power
45
analysis parameter.
PANalyze Group
:PANalyze?
Queries all settings related to the input/output of power analysis.
47
:PANalyze:JUMP
Jumps from the power analysis setup screen to the selected setup screen.
47
:PANalyze:MATH<x>?
Queries all settings related to the computed waveform MATH<x> of power analysis. 47
:PANalyze:MATH<x>:MODE
Enables/Disables the computed waveform MATH<x> of power analysis or queries
47
the current setting.
:PANalyze:PWR<x>?
Queries all settings related to the power analysis target PWR<x>.
47
:PANalyze:PWR<x>:MODE
Enables/Disables the power analysis target PWR<x> or queries the current setting. 47
:PANalyze:PWR<x>:U?
Queries all settings related to the voltage input channel of the power analysis
47
target PWR<x>.
:PANalyze:PWR<x>:U:PROBe
Sets the probe attenuation of the voltage input channel of the power analysis
47
target PWR<x> or queries the current setting.
:PANalyze:PWR<x>:I?
Queries all settings related to the current input channel of the power analysis
47
target PWR<x>.
:PANalyze:PWR<x>:I:PROBe
Sets the current-to-voltage conversion ratio of the current input channel of the
47
power analysis target PWR<x> or queries the current setting.
12 Communication Commands