37
IM CW500-02EN
Specifications
General Specifications
Bluetooth function
CW500-B0: Not available CW500-B1: Available
Measurement line
Single-phase two-wire (up to four systems), single-
phase three-wire, three-phase three-wire, three-
phase four-wire
Measured and computed items Voltage, current, frequency, active power, reactive
power, apparent power, active energy, reactive
energy, volt-ampere hours, power factor, neutral line
current, demand, harmonics, power supply quality
(swell, dip, interruption, transient overvoltage, inrush
current, unbalance factor, IEC flicker)
Other functions
Digital output, analog DCV input
Voltage
(RMS)
Range
600.0/1000 V
Accuracy
Measurement waveform
Sine wave 40 to 70 Hz at 600 V range
10% to 150% for nominal voltage 100 V or higher:
nominal voltage±0.5%
Outside the above range and 1000 V range:
±0.2% rdg ± 0.2%rng
Effective input range 1% to 120% (rms) of each range and 200% (peak) of
each range
Display range
0.15% to 130% of each range (displays 0 for less
than 0.15%)
Crest factor
3 or less
Voltage transient
sampling speed
24 µs
Current
(RMS)
Range
96060(2A type): 2A
96061 (50A type): 5/50A/AUTO
96062 (100A type): 10/100A/AUTO
96063 (200A type): 20/200A/AUTO
96064 (500A type): 50/500A/AUTO
96065 (1000A type): 100/1000A/AUTO
96066 (3000A type): 300/1000/3000A
Accuracy
±0.2% rdg ± 0.2% rng + current clamp-on probe
accuracy (sine wave, 40 to 70 Hz)
Effective input range 1% to 110% (rms) of each range and 200% (peak) of
each range
Display range
0.15% to 130% of each range (displays 0 for less
than 0.15%)
Crest factor
3 or less