20
IM CW500-02EN
Output Terminals
The output terminals normally output high level signals, but when a power
supply quality event occurs, they output low level signals while the event
persists.
Note
• If the event persists less than 1 second, a low level signal is output for
1 second.
• The output target event is the event with the highest priority among
the specified events. If you want the output to synchronize with a
lower priority event, turn off events that are higher priority.
+5V
H
L
OUTPUT
Output type:
Open collector output
Maximum input: 30 V, 50 mA, 200 mW
Output voltage: Hi –4 to 5 V
Lo –0 to 1 V
Connecting the I/O Terminals