background image

 

G.

 

PERFORMANCE DATA 

 

Arrest Force: Designed for 6 kN (1350 lbs) maximum arresting force with an energy absorbing lanyard. 

 

Maximum Capacity: 

160 Kg (352 lbs)

 when using an energy absorbing lanyard. 

 

Requirements: Meets applicable local and federal standards, Z259.2.5, Z359.15

H.

 

ROPE GRAB MAKRINGS 

 

Figure 9– Markings 
 

 

Summary of Contents for N-610LY

Page 1: ...C Enclosure D Roller Cam E Locking Roller F Detent Pin G Warning Marking H Energy Absorber WARNING This product is part of a personal fall arrest or restraint system The user must read and follow the...

Page 2: ...to limit the free fall to 1 8 m 6 feet or less per CSA Z259 2 5 See associated connecting subsystem manufacturer s instructions for additional information c FALL CLEARANCE Make certain that enough cl...

Page 3: ...pproved when used with the following synthetic lifelines 16mm MCM Superline Rope from MCM Ropes Rigging 57 316 16mm Rope from Cancord B 2 COMPATIBILITY OF CONNECTORS Fall Protection connectors i e Hoo...

Page 4: ...nce in planning your system Examples of items to be considered a ANCHORAGE Select a rigid anchorage point that is capable of supporting the required loads The anchorage location must be carefully sele...

Page 5: ...ed integrally connected shock absorbing lanyard must be protected from contact with sharp or abrasive edges and surfaces The rope grab locking operation must not be hindered by interference with the r...

Page 6: ...ing lanyard C 5 CONNECTING TO THE FULL BODY HARNESS connect to the dorsal D ring located between the shoulders on the back of the full body harness Ensure connections are compatible in size shape and...

Page 7: ...ices must be tight with five full tucks and thimbles must be held by the splice Cracked or distorted rope thimbles may indicate that the lifeline has been impact loaded Check for chemical or heat dama...

Page 8: ...1350 lbs maximum arresting force with an energy absorbinglanyard Maximum Capacity 160 Kg 352 lbs when using an energy absorbing lanyard Requirements Meets applicable local and federal standards Z259...

Page 9: ...9 INSPECTION AND MAINTENANCE LOG...

Page 10: ...tional warranties or in any way increase the scope of this warranty YOKE INDUSTRIAL will not accept liability for defects that are the result of product abuse misuse alteration or modi cation or for d...

Reviews: