YMGI WMMS-21CH Installer'S Instruction & User'S Manual Download Page 8

BRIEF UNIT INFORMA

TION

BRIEF UNIT INFORMA

TION

P14 OF 34

P13 OF 34

USER NOTES AND SERVICE LOG

OUTDOOR UNIT WORKING TEMPERATURE RANGE

Maximum cooling

Minimum cooling

Maximum heating

Minimum heating

o

Outdoor side DB( F)

115(T1)

20

75

5

SPECIFICATION

Outdoor Unit Models

WMMS-21CH-V2B(59)(2) (1 to 2)
WMMS-30CH-V2B(59)(2) (1 to 2)

WMMS-24CH-V2B(59)(2) (1 to 3)
WMMS-36CH-V2B(59)(2) (1 to 3)

WMMS-48CH-V2B(59)(2) (1 to 4)

WMMS-42CH-V2B(59)(2) (1 to 4)

Power Supply

208-230/1/60

Cooling Capacity*
(Btu/h)

Max. Allowed IDU Cap. Total

30,000

36,000

48,000

57,000

Rated

18,000

24,000

28,000

30,000

Min.

7,200

10,000

10,000

10,000

Total Power Input in 
Cooling Mode* (W)

Max.

2300

3300

4500

4500

Rated

1550

2250

2600

2600

Min.

650

800

900

1000

SEER

HSPF

16.0

8.2

16.0

8.2

16.0

8.2

16.0

8.2

Heating Capacity* 
(Btu/h)

32,000

38,000

50,000

59,000

Rated

19,000

29,500

31,000

33,000

Min.

6,500

9,000

9,000

9,000

Total Power Input in 
Heating Mode*

Max.

2400

3000

3500

3500

Rated

1750

2500

2920

2920

Min.

650

800

900

1000

WMMS-60CH-V2B(59)(2) (1 to 5)

72,000

42,000

12,000

5100

3950

1200

16.0

8.2

74,000

46,000

10,000

4800

4400

1200

Compressor Manufacturer/trademark

Liquid Valve Size

2 x 1/4"

3 x 1/4"

4 x 1/4"

4 x 1/4"

Gas Valve Size

2 x 3/8"

3 x 3/8"

4 x 3/8"

4 x 3/8"

Sanyo / Mitsubishi / Others

Sanyo / Mitsubishi / Others

Sanyo / Mitsubishi / Others

Sanyo / Mitsubishi / Others

Throttling Method

Electronic Expansion Valve

Electronic Expansion Valve

Electronic Expansion Valve

Electronic Expansion Valve

Starting Method

Transducer starting

Transducer starting

Transducer starting

Transducer starting

Recommended Working Ambient Temp Ranges (F)

AC: 20 to 115  HP: 5 to 75

AC: 20 to 115  HP: 5 to 75

AC: 20 to 115  HP: 5 to 75

AC: 20 to 115  HP: 5 to 75

Condenser

Aluminum fin-copper tube

Aluminum fin-copper tube

Aluminum fin-copper tube

Aluminum fin-copper tube 

Output of Fan Motor (W)

60

60

60

60

Fan Motor RLA (A)

0.65

0.65

0.65

0.65

Fan Motor Capacitor (uF)

3

3.5

3.5

3.5

Air Flow Rate of Outdoor Unit

/

/

/

/

Fan Type-Piece

Axial fan 1

Axial fan 1

Axial fan 1

Axial fan 1

Fan Diameter (Inches)

18.1

18.1

18.1

18.1

Defrosting Method

Auto Defrost

Auto Defrost

Auto Defrost

Auto Defrost

Climate Type

T1

T1

T1

T1

Isolation

I

I

I

I

Moisture Protection

IP24

IP24

IP24

IP24

Max. Operating Pressure at High Side (PSI)

550

Max. Operating Pressure at Low Side (PSI)

175

Sound Pressure Level dB (A) (H/L)

56/54

56/54

56/54

56/54

Sound Power Level dB (A) (H/L)

66/64

66/64

66/64

66/64

Dimensions of Outdoor Unit (W x H x D) (Inches)

33.3 x 27.0 x 11.8

37.4 X 27.5 X 15.5

37.2 X 27.6 X 15.75

37.4 X 27.5 X 15.5

Dimensions of Package (W x H x D) (Inches)

39.1 x 29.5 x 16.9

40.6 X 29.5 X 16.5

40.5 X 29.5 X 18.0

40.6 X 29.5 X 16.5

Net Weight /Gross Weight (LBs)

115 / 126

150 / 161

165 / 176

165 / 176

Refrigerant /Factory Pre-Charge for 25' (LBs)

R410A / 2.97

R410A / 4.84

R410A / 4.84

R410A / 4.84

Loading 
Quantity

20' Container

87

80

80

80

40' Container

183

170

170

170

40' High Cube Container

183

170

170

170

550

550

550

175

175

175

30

30

30/40

40

L.R.A. (A)

27

45

45

45

Compressor RLA (A)

8.4

9.7

9.7

10

Compressor Power Input (W)

1245

2200

Fuse or Circuit Breaker (HVAC Type)

MCA (A)    

15   

20   

20/30

30 

Compressor Oil

/ FV50S /

/ FV50S /      

/ FV50S /            

/ FV50S /

2200

2200

4 x 1/4" + 3/8"

2 x 3/8" + 2 x 1/2" + 5/8"

Sanyo / Mitsubishi / Others

Electronic Expansion Valve

Transducer starting

AC: 20 to 115  HP: 5 to 75

Aluminum fin-copper tube 

140

1.1

6

/

Axial fan 1

22.5

Auto Defrost

T1

I

IP24

56/54

66/64

42.25 X 43.5 X 17.5

46.0 X 48.6 X 19.4

225 / 248

R410A / 10.6

50

100

100

550

175

50

55

13

50

/ FV50S /

3000

Max. Allowed IDU Cap. Total

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World !

SAMPLE SIZE COMBINATIONS AND PERFORMANCE DATA

1) The DC inverter outdoor unit may work with many different combinations of styles (wall, ceiling, ceiling/floor, concealed, etc.) and sizes of indoor units.
2) In real world, there might be small percentage of applications where all indoor units will be working at peak demand of cooling or heating needs. One room 
    could be at peak demand, others may not. This way, the outdoor unit doesn't need to work at peak speed/load all the time.
3) Not all pairs of refrigerant valves need to be connected at initial installation. But, there is minimum amount of indoor units shall be connected (refer to the spec. 
    sheet for details). 
    If only few of indoor units are installed initially, other indoor units can still be installed in the future whenever ready (need to vacuum and adjust refrigerant 
    charge accordingly).
4) These outdoor unit can only drive all indoor units for one thermal mode at one time. Shall not run cooling in one indoor unit, and heating in another one. In 
    case of mode conflict or clash, correct the thermal mode which is different from others, or shut off power and select one thermal mode for all indoor units.

Indoor Unit 

Combinations

Total 

Capacity

Room A

Room B

Room C

Room D

Capacity Rating-Btu/h 

(Min.

Max.)

Input Power Rating-Watts 

(Min.

Max.)

WMMS-2AM21-V2B(59)(2) / WMMS-2AM30-V2B(59)(2) Cooling Performance Nominal Data

9K

9K

10880

10880 (9180~12240)

1050 (1000~1300)

12K

12K

11900

11900 (9180~14960)

1050 (1000~1500)

18K

18K

17000

17000 11220~22780)

(

1400 (1000~2600)

9+9K

18K

8500

8500

17000 11220~22780)

(

1400 (1000~2600)

9+12K

21K

8500

11900

20400 11220~26520)

(

1800 (1000~3300)

12+12K

24K

11900

11900

23800 11220~27880)

(

2300 (1000~3800)

9+18K

27K

8840

15300

24140 11220~32300)

(

2200 (1000~4600)

12+18K

30K

11900

12240

24140 11220~32300)

(

2200 (1000~4600)

9+9+9K

27K

8075

8075

8075

24140 11220~32300)

(

2200 (1000~4600)

9+9+12K

30K

7140

7140

9860

24140 11220~32300)

(

2200 (1000~4600)

9+12+12K

33K

6460

8840

8840

24140 11220~32640)

(

2200 (1000~4650)

12+12+12K

36K

8075

8075

8075

24140 11220~32640)

(

2200 (1000~4650)

9+9+18K

36K

7480

7480

9180

24140 11220~32640)

(

2200 (1000~4650)

9+12+18K

39K

7140

7820

9180

24140 11220~32640)

(

2200 (1000~4650)

12+12+18K

42K

7820

7820

8500

24140 11220~32640)

(

2200 (1000~4650)

WMMS-3AM24-V2B(59)(2) / WMMS-3AM36-V2B(59)(2)  Cooling Performance Nominal Data

9+9K

18K

8500

8500

17000 11220~22780)

(

1400 (1000~2600)

9+12K

21K

8500

11900

20400 11220~26520)

(

1800 (1000~3300)

12+12K

24K

11900

11900

23800 11220~27880)

(

2300 (1000~3800)

9+18K

27K

8840

15300

24140 11220~32300)

(

2200 (1000~4600)

12+18K

30K

11900

12240

24140 11220~32300)

(

2200 (1000~4600)

9+9K

18K

8500

8500

1400 (1000~2600)

9+12K

21K

8500

11900

1800 (1000~3300)

9+9+9K

27K

8044

8044

8044

2200 (1000~4600)

9+9+12K

30K

7140

7140

9860

2200 (1000~4600)

9+12+12K

33K

6460

8840

8840

2200 (1000~4650)

12+12+12K

36K

8044

8044

8044

2200 (1000~4650)

9+9+18K

36K

7480

7480

9180

2200 (1000~4650)

9+12+18K

39K

7140

7820

9180

2200 (1000~4650)

12+12+18K

42K

7820

7820

8500

2200 (1000~4650)

9+9+9+9K

36K

6800

6800

6800

6800

2480 (1000~4650)

9+9+9+12K

39K

1750

1750

1750

2750

2480 (1000~4650)

9+9+12+12K

42K

1500

1500

2500

2500

2480 (1000~4700)

9+12+12+12K

45K

1700

2100

2100

2100

2480 (1000~4700)

WMMS-4AM42-V2B(59)(2) Cooling Performance Nominal Data

Indoor Unit 

Combinations

Total 

Capacity

Room A

Room B

Room C

Room D

Capacity Rating-Btu/h 

(Min.

Max.)

Input Power Rating-Watts 

(Min.

Max.)

12+12K

24K

11900

11900

2300 (1000~3800)

9+18K

27K

8840

15300

2200 (1000~4600)

12+18K

30K

11900

12240

10880 (9180~12240)

11900 (9180~14960)

17000 (11220~22780)

17000 (11220~22780)

20400 (11220~26520)

24140 (11220~32300)

24140 (11220~32300)

24140 (11220~32640)

24140 (11220~32640)

24140 (11220~32640)

24140 (11220~32640)

24140 (11220~32640)

27200 (11220~32640)

23800 (11220~27880)

24140 (11220~32300)

24140 (11220~32300)

2200 (1000~4600)

Indoor Unit 

Combinations

Total 

Capacity

Room A

Room B

Room C

Room D

Capacity Rating-Btu/h 

(Min.

Max.)

Input Power Rating-Watts 

(Min.

Max.)

9+9K

10880

10880

21760 (8670~27880)

2050 (900~2950)

9+12K

10880

13600

24480 (8670~28900)

2300 (900~3300)

12+12K

13260

13260

26520 (10200~31620)

2400 (900~3500)

9+18K

9860

17000

26860 (10200~31620)

2400 (900~3500)

12+18K

12240

15300

27540 (10540~33660)

2400 (1000~3900)

9+9+9K

9180

9180

9180

27540 (10540~33660)

2400 (1000~4000)

9+9+12K

8500

8500

10540

27540 (10540~33660)

2400 (1000~4000)

9+12+12K

7480

10370

10370

28220 (10540~33660)

2450 (1000~4000)

9+9+18K

7990

7990

11560

27540 (10540~33660)

2400 (1000~4000)

12+12+12K

9690

9690

9690

29070 (10540~33660)

2500 (1000~4000)

9+12+18K

7480

9180

10880

27540 (10540~33660)

2400 (1000~4000)

12+12+18K

8500

8500

10540

27540 (10540~33660)

2400 (1000~4000)

9+9+9+9K

8160

8160

8160

8160

32640 (11220~37400)

2600 (1100~4200)

9+9+9+12K

7480

7480

7480

10200

32640 (11220~37400)

2600 (1100~4200)

9+9+12+12K

7140

7140

9180

9180

32640 (11220~37400)

2600 (1100~4200)

9+12+12+12K

18K

21K

24K

27K

30K

27K

30K

33K

36K

36K

39K

42K

36K

39K

42K

45K

6120

8840

8840

8840

32640 (11220~37400)

2600 (1100~4200)

Indoor Unit 

Combinations

Total 

Capacity

Room A

Room B

Room C

Room D

Capacity Rating-Btu/h 

(Min.

Max.)

Input Power Rating-Watts 

(Min.

Max.)

WMMS-4AM42-V2B(59)(2)  Heating Performance Nominal Data

Indoor Unit 

Combinations

Total 

Capacity

Room A

Room B

Room C

Room D

Capacity Rating-Btu/h 

(Min.

Max.)

Input Power Rating-Watts 

(Min.

Max.)

9K

9K

9860

9860 (6630~15980)

1100 (850~2450)

12K

12K

13260

13260 (6800~17000)

1450 (850~2500)

18K

18K

19720

19720 (8670~27880)

1850 (900~2950)

9+9K

18K

10880

10880

21760 (8670~29240)

2050 (900~2950)

9+12K

21K

10880

13600

24480 (8670~30600)

2300 (900~3300)

12+12K

24K

13260

13260

26520 (10200~32640)

2400 (900~3500)

9+18K

27K

12240

17000

26860 (10200~31620)

2400 (900~3500)

12+18K

30K

12240

15300

27540 (10540~33660)

9+9+9K

27K

9632

9632

9632

28900 (10540~37400)

9+9+12K

30K

9010

9010

10880

28900 (10540~37400)

9+12+12K

33K

7820

10880

10880

29580 (10540~37400)

2400 (1000~3900)

2350 (1000~4000)

2350 (1000~4000)

2400 (1000~4000)

9+9+18K

36K

7990

7990

13600

29580 (10540~37400)

12+12+12K

36K

9860

9860

9860

29580 (10540~37400)

9+12+18K

39K

7480

9180

12920

29580 (10540~37400)

12+12+18K

42K

8500

8500

12580

29580 (10540~37400)

2600 (900~3800)

2600 (900~3800)

2600 (900~3800)

2600 (900~3800)

9+9K

18K

10880

10880

21760 (8670~29240)

2050 (900~2950)

9+12K

21K

10880

13600

24480 (8670~30600)

2300 (900~3300)

12+12K

24K

13260

13260

26520 (10200~32640)

2400 (900~3500)

9+18K

27K

12240

17000

26860 (10200~31620)

2400 (900~3500)

12+18K

30K

12240

15300

27540 (10540~33660)

WMMS-3AM24-V2B(59)(2) / WMMS-3AM36-V2B(59)(2)  Heating Performance Nominal Data

WMMS-2AM21-V2B(59)(2) / WMMS-2AM30-V2B(59)(2) Heating Performance Nominal Data

Indoor Unit 

Combinations

Total 

Capacity

Room A

Room B

Room C

Room D

Capacity Rating-Btu/h 

(Min.

Max.)

Input Power Rating-Watts 

(Min.

Max.)

RECOMMENDED MATCHING INDOOR AND OUTDOOR UNITS (NOT ALL 
POSSIBILITIES BEING LISTED)

1 Indoor Unit

2 Indoor Units

3 Indoor Units

4 Indoor Units

09K

12K

18K

09K+12K

09K+09K

1 Indoor Unit

2 Indoor Units

3 Indoor Units

4 Indoor Units

4 Indoor Units

09K+12K

09K+18K

12K+12K

09K+09K+09K

09K+09K+12K

09K+09K+18K

1 Indoor Unit

2 Indoor Units

3 Indoor Units

Not allowed

Not allowed

09K+09K+12K

09K+12K+12K

09K+09K+09K+09K

09K+09K+09K+12K

09K+09K+12K+12K

12K+12K

09K+18K

09K+12K+18K

09K+09K+24K

12K+12K+18K

09K+12K+12K+12K

12K+12K+12K+12K

09K+09K+09K+18K

12K+18K

1 Indoor Unit

2 Indoor Units

3 Indoor Units

4 Indoor Units

09K+09K+09K

09K+09K+12K

09K+12K+24K

09K+12K+12K

09K+09K+09K+09K

09K+12K+12K+18K

09K+09K+09K+12K

09K+09K+12K+18K

09K+09K+09K+18K

09K+09K+12K+24K

09K+12K+12K+24K

12K+18K

09K+24K

09K+09K+18K

12K+12K+12K

09K+12K+18K

12K+12K+24K

09K+09K+09K+24K

12K+12K+12K+12K

12K+12K+18K

Not allowed

Not allowed

Not allowed

Not allowed

12K+24K

12K+24K

18K+18K

09K+12K+12K

09K+12K+18K

12K+12K+12K

18K+18K

Important Notes:

Indoor Unit Mix and Match Size Possibilities (Samples), to Work with: Outdoor Unit WMMS-21CH-V2B(59)(2) / WMMS-30CH-V2B(59)(2)

Indoor Unit Mix and Match 

Size Possibilities (Samples), to Work with: Outdoor Unit WMMS-24CH-V2B(59)(2) / WMMS-36CH-V2B(59)(2)

Indoor Unit Mix and Match 

Size Possibilities (Samples), to Work with: Outdoor Unit WMMS-42CH-V2B(59)(2)

Indoor Unit Mix and Match 

Size Possibilities (Samples), to Work with: Outdoor Unit WMMS-48CH-V2B(59)(2)

12K+12K

12K+18K

24K

1 Indoor Unit

Not allowed

Indoor Unit Mix and Match Size Possibilities (Samples), to Work with: Outdoor Unit WMMS-60CH-V2B(59)

(2)

2 Indoor Units

5 Indoor Units

09K+09K+09K+12K+12K/18K/24K

09K+12K+12K+12K+12K/18K

09K+09K+12K+12K+18K
09K+12K+12K+18K+18K

12K+12K

18K+18K

18K+24K

12K+18K

12K+24K

24K+24K

3 Indoor Units

09K+09K+09K

09K+09K+18K

12K+12K+12K

09K+09K+12K

12K+12K+18K

12K+12K+24K

09K+12K+12K

09K+12K+18K

09K+12K+24K

4 Indoor Units

09K+09K+09K+12K

09K+09K+12K+18K

09K+09K+12K+24K

09K+09K+09K+09K

09K+12K+12K+18K

09K+12K+12K+24K

09K+09K+09K+18K

12K+12K+12K+12K

12K+12K+12K+24K

09K+09K+09K+09K+12K/18K/24K
09K+09K+12K+12K+12K/18K/24K

12K+12K+12K+12K+12K/18K

09K+09K+12K+18K+18K
12K+12K+12K+18K+18K

18K+24K

18K+18K

24K+24K

18K+24K

9K+9K+9K

9K+9K+18K

12K+12K+12K

09K+12K+24K

09K+09K+12K+18K

* When the rated total capacity of all the indoor units exceeds the rated capacity of outdoor unit, each indoor unit may not output the rated 
  capacity and one may differ from other, upon other installation/operation factors, it all units are turned on to run compressor simultaneously.
* Must follow pipe length and refrigerant charge adjustment as instructed in below table:

PIPE ADAPTOR

Whenever the outdoor unit gas valve of size 3/8" is to connect with indoor unit gas pipe of 1/2" or 5/8", 
one 3/8" - 1/2" or 3/8" - 5/8" adaptor is to be used in between. This reducer is packed separately and 
shall be installed at job site.

PIPE ADAPTOR

PIPE FROM 

INDOOR UNIT

OUTDOOR UNIT VALVE

OUTDOOR UNIT WORKING TEMPERATURE RANGE

Summary of Contents for WMMS-21CH

Page 1: ...NY CHOIR OUTDOOR UNIT CH This product is designed and manufactured free from defects in material and workmanship for normal use and maintenance Installation operation maintenance and service shall fol...

Page 2: ...or your NEW home unit is not checked or used yet is closed whichever comes later by the owner s to Warranty Department YMGI Group POB 1559 O Fallon MO 63366 USA A full copy of Warranty Registration C...

Page 3: ...leakage before and after connecting them 28 Do you list the working details in the invoice and leave a copy to the customer 19 Did you charge the inter connection copper pipes and indoor unit with nit...

Page 4: ...operly can be more expensive than spending the little extra money that hiring the right contractor will cost Protect your investment and warranty eligibility by doing it right the first time THE FOLLO...

Page 5: ...ity to claim freight damage is lost and YMGI will not replace the unit on this basis Contact the distributor or YMGI report the damage by forwarding the marked delivery receipt copy and pictures Only...

Page 6: ...Service Center for Inspection and Repair and Authorization to Charge form 2 You will review the form and fill all fields appropriately sign and send back to the YMGI Group 3 Once the form has been co...

Page 7: ...rag wires too hard or use wire to hang or band or fasten anything Must turn off unit and disconnect electrical power before cleaning or servicing the unit Suggest to put a warning sign at the switch t...

Page 8: ...39K 7140 7820 9180 2200 1000 4650 12 12 18K 42K 7820 7820 8500 2200 1000 4650 9 9 9 9K 36K 6800 6800 6800 6800 2480 1000 4650 9 9 9 12K 39K 1750 1750 1750 2750 2480 1000 4650 9 9 12 12K 42K 1500 1500...

Page 9: ...a flat solid floor When mounting the unit on a wall or the roof make sure the support is firmly secured so that it cannot move in the event of intense vibrations or a strong wind Do not install the o...

Page 10: ...SIZES UNITS MADE AFTER 09 2012 Unit Connection Copper Pipe Sizes Min Max Length Elevation Wires from Outdoor to Each Indoor Unit Mini Wire Size from Outdoor to Circuit Breaker HVAC Type Circuit Break...

Page 11: ...reduce the bending of the piping line as much as possible so as to avoid possible negative impacts upon the performances of the units Make Oil trap if elevation drop difference is more than 25 as illu...

Page 12: ...N 1 2 3 N 1 2 3 D C B A Left Right YMGI Engineered Comfort Products for A Sustainable and Efficient Green World YMGI Engineered Comfort Products for A Sustainable and Efficient Green World ELECTRICAL...

Page 13: ...IRING DIAGRAMS WARNING L BN WH BL YE AC L1 AC N1 AC N3 AC L3 27RD 36RD PR N 26BK 35BK W38 W37 X5 X3 X4 U V W P N W39 AP2 AP3 AP4 PR N AC L1 AC N1 XH 3 20BN 21BU X6 X1 X101 X12 X14 19YEGN E X10 AC L X9...

Page 14: ...h Capacity Size Inch 17 7 21 7 15 4 18 3 320 360 09K 18K 18K 60K Made of stainless steel Model BRKT 0918 ST1 BRKT 1860 ST1 A B LBs Btu h Capacity Size Inch 17 7 21 7 15 4 18 3 320 360 09K 18K 18K 60K...

Page 15: ...sure the unit is ready for trial running check wires and pipes and air intake and discharge and power and thermostat and others necessary components liquid connecting pipe liquid closing valve gas co...

Page 16: ...ranty registration card If not filed or not filled completely or correctly your factory warranty may not be qualified Possible Problems or Consequences PRESSURE TABLES Warning R410A refrigerant bears...

Page 17: ...ments for the refrigerant R410A Do not use any refrigerant other than R410A Do not clean the unit using mineral oil WARRANTY AND TECH SUPPORT YMGI warrants to the purchaser owner s that YMGI products...

Page 18: ...t history No Date Service Maintenance Conducted Person Phone USER NOTES Put down whatever questions you have or problems you have seen as a unit history No Date Questions or Problems Remarks USER NOTE...