![YMGI WMMS-09C-V2A(57)2 Installer'S Instruction & User'S Manual Download Page 51](http://html1.mh-extra.com/html/ymgi/wmms-09c-v2a-57-2/wmms-09c-v2a-57-2_installers-instruction-and-users-manual_910613051.webp)
YMGI, Engineered Comfort Products for A Sustainable and Efficient Green World!
YMGI: Your Modern Green Idea
51
PROTECTION AND ERROR CODES
Self-Diagnostic Functions
Self-check information
Self-check code of running lights
Digital display self-check code
Defrost Indication
Blink 1 time / 1 sec
dF or Heating icon flashes
Anti-cold wind
Blink 1 time / 1 sec
Fan motor icon does not light up
Room temperature sensor fault
Blink 1 time / 8 sec
E2
Coil temperature sensor
Blink 2 times / 8 sec
E3
External feedback sensor fault
Blink 7 times / 8 sec
E7
Outdoor tube temperature sensor fault
Blink 4 times / 8 sec
E1
EEPROM Communication failure
Blink 6 times / 8 sec
E6
Outdoor ambient temperature exceeds
units operating range
Blink 1 time / 1 sec
FF
Note:
Above self-diagnostic information is commonly applicable in most air conditioner models, but some units do
have different codes. Please refer to the User’s Manual or contact YMGI for more information
Error Codes Display for Indoor Unit
Malfunction
Indoor Unit Display Status
Code
LED display
Running lamp flashing
frequency
Timing lamp flashing
frequency
Communication fault between the
indoor and outdoor units
F1
1
Lit
Indoor ambient temperature sensor fault
F2
2
Lit
Indoor coil temperature sensor fault
(including inlet, middle of pipe and
outlet)
F3
3
Lit
Indoor fan fault
F4
4
Lit
Outdoor module fault
F5
5
Lit
Outdoor ambient temperature sensor
fault
F6
6
Lit
Outdoor coil temperature sensor fault
F7
7
Lit
Compressor suction temperature
sensor fault
F8
8
Lit
Compressor discharge temperature
sensor fault
F9
9
Lit
Current inductor or voltage fault
FA
10
Lit
Abnormal compressor drive fault
FC
11
Lit
Power supply incorrect phase or phase
sequence fault
FD
12
Lit
Gas return sensor fault (includes A, B,
C, D)
FE
13
Lit
Low refrigerant
FF
14
Lit
Note:
The above error code information is applicable to several models of air conditioners, but because of product changes or
improvements, they can change. Please refer to