Falcon-II 

Next Generation, Air Quality Monitor 

CO2 & Temperature 

OPERATION MANUAL 

 

Critical Environment Technologies    

Canada Inc. 

Summary of Contents for Falcon-II

Page 1: ...ay Delta BC V4G 1M3 Canada Phone 604 940 7007 Fax 604 940 7044 www yestek com REV A JUNE 2 2008 Falcon II Next Generation Air Quality Monitor CO2 Temperature OPERATION MANUAL Critical Environment Tech...

Page 2: ...2...

Page 3: ...IP FOR A PERIOD OF EIGHTEEN MONTHS INCLUDING CO2 SENSOR FROM THE DATE OF PURCHASE BY THE ORIGINAL OWNER IF THE PRODUCT SHOULD BECOME DEFECTIVE WITHIN THIS WARRANTY PERIOD WE WILL REPAIR OR REPLACE IT...

Page 4: ...LIABILITY REASONS CETCI HAS A POLICY OF PERFORMING ALL NEEDED REPAIRS TO RESTORE THE INSTRUMENT TO FULL OPERATING CONDITION PRIOR TO SHIPPING EQUIPMENT TO CETCI CONTACT OUR OFFICE FOR AN RMA RETURNED...

Page 5: ...S MANUAL ALL INFORMATION CONTAINED IN THIS MANUAL IS BELIEVED TO BE TRUE AND ACCURATE AT THE TIME OF PRINTING HOWEVER AS PART OF IT S CONTINUING EFFORTS TO IMPROVE IT S PRODUCTS AND THEIR DOCUMENTATIO...

Page 6: ...E 7 1 0 GENERAL 8 2 0 SPECIFICATIONS 8 9 3 0 DIMENSIONS 10 4 0 INSTRUMENT FEATURES 11 12 5 0 OPERATION 13 5 1 OPERATING MODES 13 5 2 DETAILED OPERATING INSTRUCTIONS 13 16 5 22 OPERATION MODE ADJUSTMEN...

Page 7: ...mory The instrument may be hand held or will easily stand on a flat surface The FALCON II instruments are manufactured to provide good value to the end user Calibration and repair is available at our...

Page 8: ...wall configuration only Power Requirement 160 mA Peak 15 mA average from 6V Outputs Normally Low 100mA max 24 VDC Adjustable set point factory setting is 1000ppm hysteresis is 50ppm One RJ 45 Connecto...

Page 9: ...er C or 2 ppm per C whichever is greater referenced to 25 C Pressure Dependence 0 13 of reading per mm Hg Corrected via user input for altitude Response Time 2min for 63 of step change Warm Up Time 60...

Page 10: ...10 3 0 DIMENSIONS 6 50 165mm 3 19 81 1mm 0 96 24 3mm...

Page 11: ...INSTRUMENT FEATURES FUNCTION PUSH BUTTONS MODE UP DOWN ENTER left to right ON OFF PUSH BUTTON LED INDICATOR LCD DISPLAY TEST GAS INLET OPENING FLIP DOWN STAND ALKALINE BATTERY ACCESS DOOR WALL ADAPTER...

Page 12: ...12 4 0 INSTRUMENT FEATURES CONT D Changing Alkaline Batteries...

Page 13: ...d ALARM Alarm when CO2 concen tration exceeds one threshold alarm Alarm level can be changed through the keypad menu The audible alarm can be switched on off through the keypad menu when the speaker i...

Page 14: ...go through the following sequence Temp C Temp F Vent Rate lps Vent Rate cfm p NOTE lps refers to Liter Per Second Per Person cfm p refers to Cubic Feet Per Minute Per Person 5 22 OPERATION MODE ADJUST...

Page 15: ...e Mode button until OUTSIDE flashes 3 2 Press Enter to show OUTSIDE CO2 and PPM flashes Press Up Down to adjust the reading 3 3 Press the Enter save the setting and return to the User Mode After modif...

Page 16: ...adings since the instrument was last switched on 6 1 Press the Mode button until MAX MIN flashes 6 2 Press Enter button MAX and MIN CO2 reading shows alternating 6 3 CLR will flash if press Up Down Pr...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...20...