background image

6

 

 

Installation requirement

 

1. The product shall be free from corrosive vapors and gases in the operating environment 
and shall not contain inflammable and explosive articles.

 

2. Keep the distance between the light outlet direction and the subject at least more than 3 
meters.

 

3.The direction of the light is an optical lens. No external force can hit the glass in the process 
of operation. If the lens is damaged, it can only be used after the professional technician 
replacing the lens of the same specifications .

 

4. When the outer cover of the power cord is damaged, it must be replaced with a new power 
cord of the same specification by relevant professional personnel before use.

 

5.When the product is hung and installed, the load bearing of the hanging device shall be at 
least 3 times greater than the weight of the product, and the safety rope shall be fastened on 
the auxiliary hanging device of the lamp, and the load bearing of the safety rope shall be 
more than 3 times greater than the weight of the product.

 

6. The lens and light source of this product must be fully used together. When any part is 
damaged, it shall be replaced by relevant professional personnel before it can be used again.

 

7. In the operating environment, it must be determined that the current voltage provided is 

within the range required by this specification

 

Well grounded.

 

 

8.When changing the light source, disconnect the power first, open the head plastic cover, 
and open the bracket of the light source area, and change the light source with the same 
specification .

 

 

The company reserves the right to amend this product manual without prior notice

 

 

Controlling Board

 

Summary of Contents for YR-380BSW

Page 1: ...GUANGDONG YA GE LAI LIGHTING AUDIO LIMITED 380W Beam Wash Spot Moving Head Model YR 380BSW Please read this manual carefully before you use this machine...

Page 2: ...nstruction Instructions and remarks Section 2 Set Up Installation installation requirements Controlling Board Machine Connection Master Slave Mode Introductions Section 3 Troubleshooting Troubleshooti...

Page 3: ...lock Omega Clamp 1 4 turn Thanks for using our YR 380BSW moving beam Carefully unpack the box and check the contents to ensure that all parts are present and in good conditions If anything damaged dur...

Page 4: ...ventilation slots are blocked Fixture may carry high heat do not aim at objective exceeding 2 minutes Safe wire should be used to install machine Bearing of safe wire should be 3 times of the machine...

Page 5: ...ed by violating this manual is out of insurance our company will not take the responsibility Instructions and remarks Warning Electric shock The light source inside this lamp should be replaced by our...

Page 6: ...d the use time of light source out of timer please change the lamp Section 2 Set Up Installation Installation requirement Controlling Board Machine connection Master Slave Mode Introductions Installat...

Page 7: ...the load bearing of the hanging device shall be at least 3 times greater than the weight of the product and the safety rope shall be fastened on the auxiliary hanging device of the lamp and the load b...

Page 8: ...use of a terminator in all circumstances If you are experiencing problems with erratic fixture behavior especially over long signal cable runs a terminator may help improve performance To build your...

Page 9: ...tate connect the signal line At this time the slave machines accept the host control and the functions are synchronized with the current functions of the host Section 3 Troubleshooting Troubleshooting...

Page 10: ...respond correctly to controller D MX mode operation Defective fixture or 2 devices transmitting on link Bypass fixtures one at a time until normal operation is regained unplug both connectors and conn...

Page 11: ...2 1 Address setting Introductions Select last one or next one the lamp will automatically calculate the address code of the next one or the last one according to the current address code and channel d...

Page 12: ...X mode console mode receive DMX signal RDM signal Auto mode Fixture automatically run according to built in program Sound active mode When the lamp detects strong sound in the voice control mode the l...

Page 13: ...is no signal from DMX the fixture will operate by built in program otherwise the fixture will operate by DMX signal When the confirmation dialog box pops up select SURE to confirm the current operati...

Page 14: ...signal and goes off when there is no signal Model 2 It lights off when there is a signal and on when there is no signal DMX instruction s Model 3 The lights flashes when there is a signal and turns of...

Page 15: ...e Select the currently desired scene Scene choice 1 10 10 scene setting format Sets the retention time of the current scene when auto run Unit 0 1s 0 The current scene does not participate in automati...

Page 16: ...fter out of step and record out of step fault Set the position of zero point of Pan Pan Offset 4 150 Set the position of zero point of Tilt Tilt Offset 4 48 When setting no DMX signal of the signal th...

Page 17: ...tatus of all motors and signals in the fixture Hall Not displayed indicating that the motor has no Hall correction 0 means the motor leaves the correction position and 1 means the motor is in the corr...

Page 18: ...ted is always valid Optocouple r fault No valid optocoupler signal detected when motor reset Out of step Corresponding motor out of step during operation Bump rod When the motor is reset bump the posi...

Page 19: ...reference for after sales maintenance Device The name of the fixture the same as the device information of the RDM Model Model of the luminaire same as the model information of the RDM Display board D...

Page 20: ...eed 0 255 From fast to slow 0 127 no CH6 Frost 128 255 Enter the frost CH7 Dimmer 0 255 0 100 dimmer 0 3 Lights close 4 103 From slow to fast Pulse strobo 104 107 Lights on 108 207 From slow to fast S...

Page 21: ...or 6 60 64 Color 6 65 69 Color 6 Color 7 70 74 Color 7 75 79 Color 7 Color 8 80 84 Color 8 85 89 Color 8 Color 9 90 94 Color 9 95 99 Color 9 Color 10 100 104 Color 10 105 109 Color 10 Color 11 110 114...

Page 22: ...ows 0 9 white 10 14 Pattern 1 15 19 Pattern 2 20 24 Pattern 3 25 29 Pattern 4 30 34 Pattern 5 35 39 Pattern 6 40 44 Pattern 7 CH10 Gobo 45 49 Pattern 8 50 54 Pattern 9 55 59 Pattern 10 60 64 Pattern 1...

Page 23: ...to fast Shake pattern 8 120 124 From slow to fast Shake pattern 9 125 129 From slow to fast Shake pattern 10 130 134 From slow to fast Shake pattern 11 135 139 From slow to fast Shake pattern 12 140...

Page 24: ...121 130 From slow to fast Shake pattern 3 131 140 From slow to fast Shake pattern 4 141 150 From slow to fast Shake pattern 5 151 160 From slow to fast Shake pattern 6 161 170 From slow to fast Shake...

Page 25: ...110 From slow to fast Shake pattern 3 111 120 From slow to fast Shake pattern 4 121 130 From slow to fast Shake pattern 5 131 140 From slow to fast Shake pattern 6 141 150 From slow to fast Shake pat...

Page 26: ...r prism 2 0 127 0 400degrees 128 187 From fast to slow Forward flows 187 195 Stop CH17 Prism 2 self rotate 196 255 From slow to fast Reverse flows CH18 zoom 0 255 From small to large CH19 focusing 0 2...

Page 27: ...ntrol Mode DMX512 master slave auto Touch screen Display LCD color screen can set the channel mode horizontal vertical inversion back screen signal hint switch in both Chinese and English automatic sc...

Page 28: ...ffect Prism 8 facet 16 facet X Y scan Three phase motor pan 540 tilt 270 photoelectric reset and correction Beam Angle Linear focusing zoom 2 3 56 Working parameters Voltage AC100V 240V 50 60Hz Power...

Page 29: ...28 Net weight 23 45KG Size 409 9 323 9 670 5mm...

Reviews: