17
Optocouple
r
Display the status of the two signals of
the pan and tilt optocouplers, binary
Display the last 8 fault records of the lamp reset and
operation. The fault record is not saved after power off
。
Fault data
Total number of faults detected after
power-on
12
:
:03
Power-on
time
when
the
fault
occurs,unit is in minutes
Hall fault
The motor does not detect a valid Hall
signal when the motor is reset.
Hall short
circuit
when the motor is reset,the Hall signal
detected is always valid.
Optocouple
r fault
No valid optocoupler signal detected
when motor reset
Out of step
Corresponding motor out of step during
operation
Bump rod
When the motor is reset,bump the
positioning rod
Lamp
failure
The bulb is accidentally extinguished
Sensor
fault
The temperature sensor signal is
abnormal,
Fault/ state us
record
Fan fault
The main fan is not working properly.
Display key status data of the current fixture for
reference
Communic
ation
0~100%, Communication quality of the
internal data of the luminaire
Error count
The total number of error frames
detected after power-on, accumulated
Fixture status
Light
Display the temperature of the current