background image

ICONS AND INDICATORS ON THE LCD DISPLAY

TURNING THE THERMAL IMAGER ON AND 

CHARGING THE BATTERY

Press and hold the Power Button for greater than 2 seconds to turn the 
thermal imager ON.  A start-up screen (a thermal image) will appear.  The 
unit is now ready to use.  To turn the imager OFF, press and hold the Power 
Button for greater than 2 seconds.  Note:  The 52070F has an Auto Power 
Off function which automatically turns the thermal imager off after a period 
of inactivity.  You can set the Auto Power Off time in the Set Up Menu

With the thermal imager ON, the battery level indicator will display the 
current battery power level.  If the battery power is low, connect to an AC 
source or a computer USB port using the supplied USB cable (USB connec-
tion port is located at the top of the imager).
When the imager is powered OFF, the battery charging red LED will turn on 
when the imager is connected to an AC source or connected to a computer 
USB port.   The battery is fully charged when the red charge indicator LED 
turns off.
The imager can also be turned ON and in use while the battery is charging.   

BASIC OPERATION

The 52070F thermal imager is intuitive and easy to use.  The 52070F has an 
IR resolution of 80 x 80 or 6400 temperature measurement points.    Here 
are the basic steps (Covered in more detail later in this Guide): 

1.Press and hold the Power Button for greater than 2 seconds to turn 
  the imager ON.  The startup screen will appear followed by a thermal 
  image on the display.  Take note of the battery charge level.  

2.Point the unit toward the area or object of interest and view the 
  thermal image.  Relative temperature is represented by color, hot 
  to cold.  The Center Temperature Reading (large temperature reading 
  on the bottom of the LCD display) represents the temperature at the  
  Center Crosshair.   At the same time, the hottest and coldest point 
  temperatures in the scene will be displayed on the screen. 
3. Press the trigger briefly to capture an image of the scene.  Press the 
  OK button to save the image.  Press “SHARE” to send the image to a 
 Bluetooth

®

 connected smart device.  Press the Trigger again to 

  discard the image.
4. Press “LOCK” to lock the current scene temperature range.  Press 
“LOCK” again to un-lock the current scene temperature range.

°C/°F/k

Temperature Units

H

Max Temperature Readings

C

Minimum Temperature Readings

Hold

Freezing Image Icon

AM

12 Time Format
IRON Color Palette
Unlock Icon

Centre Crosshair

Hot Crosshair

Cold Crosshair

Bluetooth

®

 Icon

Battery Empty
Battery Full
Battery Charging
Lock Icon

Summary of Contents for 52070F

Page 1: ...ellow JacketTM 52070F Thermal Imager Contents Made in China Fabriqu en Chine Product distributed by Produit distribu par Southwire Company LLC One Southwire Drive Carrollton GA 30119 2020 Southwire Co...

Page 2: ...UTHWIRE COMPANY DOES NOT WARRANT GUARANTEE OR MAKE ANY REPRESENTATIONS REGARDING THE USE OF OR THE RESULT OF THE USE OF THE PROGRAM IN TERMS OF CORRECTNESS ACCURACY RELIABILITY CURRENTNESS OR OTHERWIS...

Page 3: ...person s surface skin temperature at a time Position the person at a fixed distance of 3 feet 1 meter from the thermal imaging system directly facing the camera Recommended viewing angle is approxima...

Page 4: ...Interface 13 Tripod mounting hole THE THERMAL IMAGER DISPLAY 1 Current Emissivity Setting 2 Battery Charge Level Indicator 3 Hot Temperature Point Reading 4 Cold Temperature Point Reading 5 Center Cr...

Page 5: ...sy to use The 52070F has an IR resolution of 80 x 80 or 6400 temperature measurement points Here are the basic steps Covered in more detail later in this Guide 1 Press and hold the Power Button for gr...

Page 6: ...than 2 seconds to turn the imager ON The start up screen will be shown until the shutter resets the image After the startup period the imager will display a real time IR thermal image along with an IR...

Page 7: ...re the image 3 To discard the image short press the trigger again The display will return to a live image 4 Press SAVE to save the image to memory 5 If the image is stored successfully on the internal...

Page 8: ...he Setup Menu buy pressing the Down Arrow button 3 Press the OK button to enter Setup menu There are three available options Bluetooth Brightness and Auto Off 4 Turn Bluetooth ON 5 Run the Thermview a...

Page 9: ...E TEMPERATURE To help in identifying and diagnosing problems the 52070F thermal imager allows you to lock the temperature range of the current scene that you are viewing TO LOCK THE SCENE TEMPERATURE...

Page 10: ...surement is as accurate as possible TEMPERATURE UNITS 1 Press OK Button to open the Settings Menu 2 Press OK Button to select this option The color of option value will change to black C 3 Use the RIG...

Page 11: ...the brightness of the LCD display brightness Press the ESC OK button to exit The avail able brightness range is 10 to 100 in 10 steps Auto Power Off Press OK Button to select this option Use the UP or...

Page 12: ...nload and run Thermview for iOS Please search in Apple store with keyword Thermview download and run DATE AND TIME Press OK Button to enter the Time Date menu The changes that you make to the date and...

Page 13: ...pictures SCREEN CAPTURE While in Thermal imaging mode use HOLD Button to enter the HOLD mode as show below Press the OK Button to capture the image on the LCD display After the image has been saved to...

Page 14: ...ect temperature 0 C MEASUREMENT ANALYSIS Spotmeter Center Spot Automatic Hot Cold Detection Auto hot or cold markers Emissivity Correction 8 pre define level and Variable from 0 01 to 1 0 STORAGE OF I...

Page 15: ...3 74 1 D S measure 1 IFOV measure is the spot size needed to provide an accurate temperature measure Typically D S measure is 2 to 3 times smaller than D S theoretical which means the temperature mea...

Page 16: ...02 2 F de 34 a 39 C La c mara de im genes t rmicas viene calibrada de f brica con una fuente de referencia de temperatura de cuerpo negro No es necesario realizar una calibraci n in situ Cumple con lo...

Page 17: ...pec fico de uso deben determinar la importancia de cualquier caso de fiebre o temperatura elevada seg n la medici n de la temperatura en la piel por termograf a La c mara de im genes t rmicas se debe...

Page 18: ...por mucho tiempo encender la linterna led Si presiona el bot n por mucho tiempo otra vez apagar la linterna led PREPARACI N DE LA PERSONA A EXAMINAR La persona que opera el sistema de diagn stico por...

Page 19: ...e flecha hacia arriba 4 Bot n de encendido y para volver 5 Bot n de flecha hacia abajo 6 Tapa de la bater a 7 Fijaci n de la cuerda de seguridad 8 Linterna led 9 Lente para im genes IR 10 Disparador 1...

Page 20: ...r de nivel de carga de la bater a 3 Lectura de puntos de temperatura de calor 4 Lectura de puntos de temperatura de fr o 5 Punto de mira medio 6 Punto de mira de temperatura de fr o 7 Punto de mira de...

Page 21: ...equipo hacia la zona o el objeto que le interesa y observe la imagen t rmica La temperatura relativa est representada por colores de caliente a fr o La lectura de la temperatura media de gran tama o...

Page 22: ...I N DE TEMPERATURA ELEVADA EN LA PIEL Si desea utilizar el term grafo para la detecci n de temperatura elevada en la piel aseg rese de que el modo de detecci n del men Measure Medir est activado El mo...

Page 23: ...Thermview instalada 1 Presione el bot n OK Aceptar para ingresar al men Settings Ajustes 2 Presione el bot n de la flecha hacia abajo para acceder al men Setup Configuraci n 3 Presione el bot n OK Ac...

Page 24: ...TOOTH 1 Presione el bot n OK Aceptar para ingresar al men Settings Ajustes 2 Presione el bot n de la flecha hacia abajo para acceder al men Setup Configuraci n 3 Presione el bot n OK Aceptar para ingr...

Page 25: ...esta opci n El color del valor seleccionado cambiar a C en negro 3 Use el bot n RIGHT MENU DERECHA MEN para alternar entre C F y k use el bot n ESC OK SALIR ACEPTAR para salir del estado de enfoque y...

Page 26: ...endurece configurar a la emisividad a 0 94 consulte el gr fico que figura a continuaci n para que la medici n sea lo m s precisa posible Substance missivit thermique Substance missivit thermique Aspha...

Page 27: ...00 en incrementos de 10 Apagado autom tico presione el bot n OK Aceptar para seleccionar esta opci n Use los botones de flecha hacia arriba o abajo para configurar el per odo de tiempo despu s del cua...

Page 28: ...memoria INFORMACI N Presione el bot n OK Aceptar para ingresar al men Information Informaci n Este men muestra la versi n del hardware y del software del term grafo FECHA Y HORA Presione el bot n OK...

Page 29: ...seleccionar la imagen previa o la siguiente 2 Presione cualquier otra tecla para salir del modo Image Browser Explorador de im genes 1 Nombre de archivo de la imagen actual 3 2 rea de visualizaci n de...

Page 30: ...MEDICIONES Fot metro Punto medio Detecci n autom tica de fr o o calor Marcadores autom ticos de fr o o calor Correcci n de emisividad Ocho niveles predefinidos y vari ables de 0 01 a 1 0 ALMACENAMIENT...

Page 31: ...ra proporcionar una medici n precisa de la temperatura Por lo general la medici n de D S es de 2 a 3 veces menor que el D S te ri co Esto significa que la zona de medici n de la temperatura del objeti...

Reviews: