background image

18 

Ritchie Engineering Co., Inc. 
Recovery Division 
6701 W. 110th St. 
Bloomington, MN 55438 USA 

Phone: 952-943-1333 or 800-769-8370 
Fax:     952-943-1140 or 800-322-8684 

E-mail: [email protected] 
Web Site: www.yellowjacket.com 

Printed in U.S.A   

 

 

 

06/07 FK                                                                               P/N 380466 REV B 

LIMITED WARRANTY 

We guarantee Ritchie YELLOW JACKET

®

 products to be free of defective material and workmanship which 

would affect the life of the product under normal use for the purpose for which it was designed. 

 
This warranty does not cover items that have been altered, abused, misused, improperly maintained, or re-
turned solely in need of field service maintenance. This warranty expressly excludes Vacuum Pump damage 
and failures caused by failure to maintain clean, uncontaminated oil in the pump – the major reason for pump 
returns. Therefore, problems related to non-maintained oil will void this warranty on that part of the product. 
 
This warranty does not cover abuse, damage from over tightening valves, or broken gauges. “Series 41” 
Manifold valves can be reconditioned using replacement seating cylinder 41133. There will be a recondition-
ing charge for manifolds returned to the factory for repair. 
 
If found defective, we will upon compliance with the return instructions either credit, replace, or repair, at our 
option, the defective product provided it is returned within one year of the date of factory shipment (90 days 
for tubing tools). Note: Hoses are Date Coded to help determine age of hose. See recommended hose safety 
inspection procedure. Leak Detectors have date of manufacture label on product. 
 
Correction in the manner provided above shall constitute a fulfillment of all liabilities with respect to the qual-
ity, material and workmanship of the product. 
 

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OF QUAL-

ITY, WHETHER WRITTEN, ORAL OR IMPLIED. 

 

 

Returns (Warranty) 

For HVAC&R Recovery Units and for Automotive Recovery, Recycle, Recharge equipment, call 1-800-
769-8370 for instructions for service, repair, or return.

 Our automatic series (Models 39870, 39750, 

39751, 39770, 39771, 39830, 39832, 39833, 39840, 39841, 39842, 39843) has a two year full parts and labor 
warranty, the semi– automatics (Models 39710, 39711, 39730, 39731, 39732, and 39733) and hand held ma-
chines (Models 39702 and 39704)  have a full one years parts and labor warranty. For all other products, 
please return warranty items to the main factory in Bloomington, MN, prepaid for credit, replacement, or re-
pair, at our option. No authorization is required. All returns must be PREPAID. On direct drive pumps, many 
of the problems can be solved over the telephone. Call 952-943-1333. 
 

Returns (Non-Warranty) 

Prior authorization must be obtained from home office for non-warranty returns. All returns must be PRE-
PAID. Minimum restocking charge 20% on standard items of current date coding and manufacture. Special 
production items will have a higher restocking charge. Many items shown in our price list are custom-
fabricated to customer’s order. 

Warranty Information

 

Summary of Contents for 39830

Page 1: ...For Automotive Applications Model 39830 Operation Manual YELLOW JACKET Automatic Refrigerant Recovery Recycling Recharging Flushing System...

Page 2: ...th Deliberate inhalation of refrigerants is extremely dangerous Death can occur without warning Vapors reduce oxygen available for breathing and are heavier than air Decomposi tion products are hazard...

Page 3: ...nting when disconnecting from the automobile Only Use the Model 830 Series with the Correct Refrigerants See the specifications for a list of compatible refrigerants Operate the Unit within the Design...

Page 4: ...Side Hose Red 5 Auto Low Side Hose Blue 6 Tank Liquid Hose Red 7 Tank Vapor Hose Blue 8 Oil Drain Bottle 9 Oil Inject Bottle 10 Tool Tray 11 Main Power Switch 12 Oil Inject Switch 13 Circuit Breaker...

Page 5: ...m This mode is most often used prior to opening an A C system to atmosphere to replace a system component 2 MODE 2 Vacuum Charge is used to Vacuum air from a system previously opened to the atmosphere...

Page 6: ...ollow the user prompts to complete the tank refill process 6 When the display reads SUPPLY TANK EMPTY disconnect blue hose 7 Remove the tank refill adapter from empty R134a virgin cylinder and place i...

Page 7: ...ED REFRIGERANT WILL VOID ALL WARRANTIES AND MAY CAUSE DAMAGE TO OTHER AUTOMOBILES THAT YOU SERVICE IN THE FUTURE During the recovery operation refrigerant is removed from both the high and low side of...

Page 8: ...on and press ENTER to accept the vacuum hold time shown on the LCD Vacuum hold time can be bypassed if the time is set to zero Answer Ques tion OIL INJECT PAUSE Y 9 The LCD should read PUSH START 10 P...

Page 9: ...es and disconnect the high and low side auto service hoses from the auto mobile 11 Press the RESET key to return to the SELECT MODE status The Full Cycle function of the Model 830 is designed to remov...

Page 10: ...recovered oil in a proper manner 19 Press the RESET button to return to the SELECT MODE status 10 Mode 5 Oil Flush The Oil Flush mode is designed to remove oil from an automobile A C system so new oi...

Page 11: ...measurement during charging is extremely accurate In recovery mode however accuracy is plus or mi nus three ounces based on variations in air tempera ture and pressure Uses of the refrigerant data inc...

Page 12: ...wer the non condensable gas value below the limit The purge time is set to 30 seconds to minimize refrigerant loss If the LCD continues to display an E after several purge cycles there may be an error...

Page 13: ...Refill with proper amount and type of oil The proper oil charge is 8 0 ounces or 225 cc s of Artic 22 Castrol SW 22 POE oil 4 Replace oil port cap and front cover 5 Dispose of oil properly Note Failu...

Page 14: ...f the unit The red service hose will be the only component containing refrigerant when the cycle is complete The outside of the filters will develop frost during evacuation This is normal and indicate...

Page 15: ...echnical Services Call Technical Services Call Technical Services Call Technical Services Fan not running in any cycle Loose power wire to fan Microprocessor malfunction Fan malfunction Locate loose f...

Page 16: ...Call Technical Services Tank or scale misaligned Reposition tank and scale Time Limit during recovery cycle A C system has a leak Locate and repair leak Valves on service hoses shut Open valves Servic...

Page 17: ...ircuit Breaker 15 Amp 95257 6 Fan Motor Assembly Part Description 27296 R 134a Auto Low Side Blue Hose 10ft 27696 R 134a Auto High Side Red Hose 10ft 00849 R 134a Tank Vapor Blue Hose 30in 00853 R 134...

Page 18: ...bing tools Note Hoses are Date Coded to help determine age of hose See recommended hose safety inspection procedure Leak Detectors have date of manufacture label on product Correction in the manner pr...

Reviews: