4) Enter the MASTER CONTROLLER interface of the software, which do not need to make any
settings, just click [Send] on the bottom.
Setting Description:
[Video source]:
The video source is set to [Auto].
[Load Divided]:
A tape-shaped partition dividing fixed field.
[Horizontal Start]:
large-screen display setting area start X-axis position, in the upper left corner
coordinates of the display starting point for the calculation of lateral body of the screen to display the
original point of the starting position is 0 by default.
[Vertical start]:
large-screen display setting area Y-axis starting position, the starting point to
calculate longitudinal crystal display screen to the upper left corner of the display coordinates of the
starting point for the original default position is 0.
[Horizontal width]:
set the actual width Mdea load, the default is 1024.
[Vertical height]:
set the actual height Mdea load, the default is 600.
[Net port height]:
Setting master first image data output port maximum height.
[Network interface backup]:
to set the replication relationship between host ports.
[Screen Mode]:
Set a specific type of the display, the function for expansion. Reserved.
[Screen Switch]:
Off, black screen, nothing is displayed; open the screen to normal playback. The
default setting is on.
[Still images]:
open, active window to freeze the picture of the current screen; off, normal playback
screen. The default setting is OFF.
[Power Off]:
used to control display power switch, this feature not yet open.