If the accumulative running time of the fan is ≥ 30 days, the machine will
continue to run
and prompt " "
which won't disappear even the
machine is powered on again.
In the power off state, press and hold the
"Function" button for a few seconds, then the display will show one time
and "
" prompt will be released. The fan running time will be cleared.
Memory Function
Defrost Function
Temperature Protection Function
Cleaning Remind Function
Special Note:
When power resumes, the machine will work at the same settings before
power outage.
When frost builds up on the evaporator coils, the compressor will cycle off
and the fan will continue to run until the frost disappears.
When the ambient temperature is higher than the default temperature of
113
℉
, the system will activate high-temperature protection, the small
number will indicate "HH" and the compressor will stop working. When the
ambient temperature is lower than the default temperature of 39
℉
, the
system will activate low-temperature protection, the small number will
indicate "LL" and the compressor will stop working.
To avoid any damages to the dehumidifier, it will not start to operate after
a complete cycle within 3 minutes. The compressor will automatically
start to work after 3 minutes.