background image

110V 50L INDUSTRIAL DEHUMIDIFIER

MODEL NO: 

SDH50110V

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1. 

 

 

ELECTRICAL SAFETY 

 

‰

  

WARNING!

 It is the responsibility of the owner and the operator to read, understand and comply with the following:

 

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and    

 

any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate  

 

safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also recommend  

 

that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are plugged into a  

 

supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual Current Device by  

 

contacting your Sealey stockist. 

 

9

  

You must also read and understand the following instructions concerning electrical  

 safety.

1.1.1.   

The 

Electricity at Work Act 1989 

requires that all portable electrical appliances, if  

 

used on business premises, are tested by a qualified electrician, using a Portable  

 

Appliance Tester (PAT), at least once a year.

1.1.2.   

The 

Health & Safety at Work Act 1974 

makes owners of electrical appliances    

 

responsible for the safe condition of those appliances and the safety of the appliance  

 

operators. If in any doubt about electrical safety, contact a qualified electrician.

 

9

   Ensure that the insulation on all cables and on the appliance is safe before connecting  

  it to the power supply.

 

9

   Ensure that cables are always protected against short circuit and overload.

 

9

   Regularly inspect power supply cables and plugs for wear or damage and check all  

  connections to ensure that none are loose.

 

9

 

 

Ensure that the voltage marked on the appliance matches the power supply to be  

 used.

 

8

  

DO NOT

 pull or carry the appliance by its power supply lead.

 

8

  

DO NOT 

pull the plug from the socket by the power cable.

 

8

  

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any  

  faulty item repaired or replaced by a qualified electrician. 

 

9

   Ensure the unit is correctly earthed via a three-pin 110V plug.

 

 

a)   Connect the GREEN/YELLOW earth wire to the earth terminal ‘PE’.

 

b)   Connect the BROWN live wire to the live terminal ‘L/+’.

 

c)   Connect the BLUE neutral wire to the neutral terminal.

 

d)   After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer insulation extends  

 

      past the cable restraint and that the restraint is tight.

1.2.    

GENERAL  SAFETY

 

9

   Check that the dehumidifier is in sound condition and good working order. Take immediate action to repair or replace damaged parts.

 

9

   Use recommended parts only. Unauthorised parts may be dangerous and will invalidate the warranty.

 

8

  

DO NOT

 stand or place any object less than 10cm from the front or rear of the unit.

 

8

  

DO NOT

 obstruct the air intakes or outlets of the dehumidifier.

 

8

  

DO NOT

 place any object into the outlets - the unit has a fan running at high speed, contact with this will cause injury.

 

8

  

DO NOT

 operate the dehumidifier when you are tired or under the influence of alcohol, drugs or intoxicating medication.

 

8

  

DO NOT

 switch the dehumidifier off by disconnecting it from the mains. ALWAYS switch to the “OFF” position first.

 

8

  

DO NOT

 remove the float lever from the water collection tank.

 

8

  

DO NOT

 connect or disconnect the plug from the mains with wet hands.

 

9

   Always discard the water from the collection tank, 

DO NOT

 use it for any other purpose.

 

9

   Place the dehumidifier on a level and stable surface.

 

8

  

DO NOT

 use the dehumidifier at ambient temperatures below 5°C.

 

8

  

DO NOT

 use the dehumidifier outside.

 

8

  

DO NOT

 use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.

 

9

   The appliance shall be stored in a room without continuously operating ignition sources (for example: open flames, an operating gas  

  appliance or an operating electric heater.)

 

8

  

DO NOT

 pierce or burn.

S

DH50110V Issue 2 12/07/2021

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Do not cover

Indoor use only

Caution: 

Risk of fire

Summary of Contents for SDH50110V

Page 1: ... and check all connections to ensure that none are loose 9 Ensure that the voltage marked on the appliance matches the power supply to be used 8 DO NOT pull or carry the appliance by its power supply lead 8 DO NOT pull the plug from the socket by the power cable 8 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician ...

Page 2: ... the appliance Cleaning and user maintenance shall not be made by children without supervision WARNING If the power cord is damaged it must be replaced by a professionally trained person 2 INTRODUCTION Powerful dehumidification capacity extracts up to 50 litres of water per day Removes excess moisture from air preventing build up of mildew and mould Features auto defrost function which activates i...

Page 3: ...tandby state the LED displays the Full Water signal and the dehumidifier will alarm When the water tank is emptied and put in place again the dehumidifier can continue its performance 5 1 2 CONTINUOUS DRAINAGE As shown in Fig 3 to restore the performance of the water tank you need to take out the water tank and mount the drain pipe Note When using continuous drainage the drainage pipe shall not be...

Page 4: ...during the defrosting operation The defrosting led light fig 4 7 will light up NOTE This dehumidifier does not have a cooling function it produces heat during the operation and room temperature will rise by 1 C to 4 C The temperature gets higher while it is operated in a closet or similar Furthermore room temperature will rise because doors and windows are closed and heat is produced from other ap...

Page 5: ... entire machine is defrosting Wait for the completion of defrosting cycle Unfavourable dehumidifying effect If the air inlet outlet is obstructed Remove the obstacle If the door and window are open Close the door and window If the indoor temperature is too low Don t run the dehumidifier Heavy noise If the ground is firm and flat Resettle the dehumidifier Dehumidifier is stood precariously Resettle...

Reviews: