background image

 

9

   Be aware that refrigerants may not contain an odour.

 

9

   When using continuous draining, make sure that the drain hose is positioned correctly.

 

9

   Ensure that heating appliances are not exposed to the flow of air from the dehumidifier.

 

9

   Before attempting to move the dehumidifier, empty the contents of the collection tank.

 

9

   Switch off and disconnect it from the mains before attempting any cleaning or other maintenance work.

 

9

   Ensure that the dehumidifier is correctly turned off when not in use, and stored in a safe, dry area, out of reach of children.

 

This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental  

 

 

capabilities or lack of experience or knowledge if they have been given supervision or instruction concerning use of the appliance in  

 

a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall  

 

not be made by children without supervision.

 

‰

  

WARNING:

 If the power cord is damaged, it must be replaced by a professionally trained person.

2.  INTRODUCTION

P

owerful dehumidification capacity, extracts up to 50 litres of water per day. Removes excess moisture from air, preventing build-up of mildew 

and mould. Features auto-defrost function, which activates if the room temperature falls too low. The unit has a 24hr timer function for delay 

starting and auto shut-off. Washable activated carbon air filter. Refrigerant is environmentally friendly R290. May be connected to a drain hose 

for continuous operation. Mounted on castors for manoeuvrability. Fitted with 110V plug.

3.  SPECIFICATION

MODEL NO: .......................................................................................SDH50110V

F

reezing Pressure (Max): ...........................................................................

2.5MPa

Global Warming Potential (Rating): .......................................................................3

IP Rating: ........................................................................................................ IP22

M

aximum Airflow:

 ..................................................................................... 300m³/hr

Power: ...............................................

600W ( 27°C RH60%)  800W(30°C RH80%)

Refrigerant: ..........................................................................................

R290/0.2kg

Steaming Pressure (Max): ......................................................................... 1.0MPa

Supply: ............................................................................................................110V

Working Space: .......................................................................................

50-120m³

Working Temperature: .................................................................................

5-35°C

fig.1

S

DH50110V Issue 2 12/07/2021

Original Language Version

© Jack Sealey Limited

Summary of Contents for SDH50110V

Page 1: ... and check all connections to ensure that none are loose 9 Ensure that the voltage marked on the appliance matches the power supply to be used 8 DO NOT pull or carry the appliance by its power supply lead 8 DO NOT pull the plug from the socket by the power cable 8 DO NOT use worn or damaged cables plugs or connectors Immediately have any faulty item repaired or replaced by a qualified electrician ...

Page 2: ... the appliance Cleaning and user maintenance shall not be made by children without supervision WARNING If the power cord is damaged it must be replaced by a professionally trained person 2 INTRODUCTION Powerful dehumidification capacity extracts up to 50 litres of water per day Removes excess moisture from air preventing build up of mildew and mould Features auto defrost function which activates i...

Page 3: ...tandby state the LED displays the Full Water signal and the dehumidifier will alarm When the water tank is emptied and put in place again the dehumidifier can continue its performance 5 1 2 CONTINUOUS DRAINAGE As shown in Fig 3 to restore the performance of the water tank you need to take out the water tank and mount the drain pipe Note When using continuous drainage the drainage pipe shall not be...

Page 4: ...during the defrosting operation The defrosting led light fig 4 7 will light up NOTE This dehumidifier does not have a cooling function it produces heat during the operation and room temperature will rise by 1 C to 4 C The temperature gets higher while it is operated in a closet or similar Furthermore room temperature will rise because doors and windows are closed and heat is produced from other ap...

Page 5: ... entire machine is defrosting Wait for the completion of defrosting cycle Unfavourable dehumidifying effect If the air inlet outlet is obstructed Remove the obstacle If the door and window are open Close the door and window If the indoor temperature is too low Don t run the dehumidifier Heavy noise If the ground is firm and flat Resettle the dehumidifier Dehumidifier is stood precariously Resettle...

Reviews: