background image

Summary of Contents for yasnac MX2

Page 1: ...Program Block 27 4 6 3 Modifying Part Program Block 28 4 6 4 Adding Part Program Insert Key 28 4 7 SUPPLEMENT TO DATA INPUT OUTPUT INTERFACE 29 4 7 1 Types and Funclions of Interface 29 4 7 2 Setting...

Page 2: ...of NC operator s panel with CRT display The names and functions of operator s devices are as follows s AODRESS BBSS BOBO 0000 3000 ilffli 0011 0 0000 _ DATA_ _ 0g HR 0000 000 GJ0O0 T I I T I M n YASK...

Page 3: ...B000000000B POWER DATA ADDRESS 0 0000 0000 0000 00SQ000 00000SS 00001100 00B0000 0 S CURSOR 000 00 00 NC Operator s Station with 14 CRT Character Display Keyboard below CRT Fig 4 2 3...

Page 4: ...functions are changed according to the NC unit operation mode these keys may be called soft keys ADORCSS 00 0 000 Fig 4 2 r r ri i r T i i 1 4 1 2 14 CRT CHARACTER DISPLAY YASNAC According to each ope...

Page 5: ...nt positions h OFS Offset key Select this key for display or writing in of tool offset values 4 1 4 ADDRESS KEYS These keys are to designate an address charac ter when writing in various data e ADDRES...

Page 6: ...played by PRM key this key is pressed to display the parrameter number to be specified Depressing 0 key moves the cursor for ward Depressing A key moves the cursor for ward Keepint the cursor control...

Page 7: ...rations to be executed by this RESET key are Move command cancel Buffer register clear code release if the cause is eliminated Tool offset cancel Auxiliary function cancel Label skip function ON Memor...

Page 8: ...Theinternal timer will be read in about two seconds Then the servo power is ready for turning on which is shown by alarm code 310 Depress the POWER OFF pushbutton to cut off the control power EMERGENC...

Page 9: ...IS PARAMETER SETTING COMMAND YASNAC MACHINE PROGRAM POSITION OFFSET REMOTE OFF BUTTON EON O TU01 24 EOF REMOTE ON BUTTON TU01 25 COM c TU01 26 Fig 4 13 Connections of Remote ON OFF Pushbuttons FUNCTIO...

Page 10: ...me key Generally CAN key INPUT ERROR Format error of keyed in data The same number of part program has been stored already EDIT LOCK ON Editing operation is made with Edit Lock on MEMORY OVER Part pro...

Page 11: ...STT I 3 In the MDI operation the current block data are displayed after cycle is indicated L LDisplay of non modal G code Display of G code under execution 4 3 2 2 DISPLAY OF REMAINING NUMBER OF REPET...

Page 12: ...gnated is erased Fig 4 17 Example of Display of Tool Offset State 2 INS key This key inserts the data which has ust been entered to the location which is next to the word the cursor points to 3 ALT ke...

Page 13: ...is indicated by the flashing letter Mode E is possible only when the system NOTE No switch is set at 4 4 3 4 1 CURRENT POSITION DISPLAY UNIVERSAL POSITION UNIVERSAL Pk OL WAM fc D J I 01234 NS6 G The...

Page 14: ...modes and even during operation 4 3 4 3 CURRENT POSITION DISPLAY IN CREMENT POSITION INCREMENT Displayed in this mode are In automatic mode distance to the end point of the block at every moment In m...

Page 15: ...5 DISPLAYING AND WRITING TOOL OFFSET DATA Tool offset data are stored in the memory of the control written in any mode and even during automatic operation These data may be displayed and re The prece...

Page 16: ...eady read m the buffer for advance reading RDY liTFlrf 0 584 332 Fig 4 25 Setting Deciaml model Example Decimal mode Setting numbers of 6200 6219 and 6500 6599 are associated with setting data of deci...

Page 17: ...te the cursor at a desired bit position Parameters are displayed either in decimal mode in binary mode 4 Depress the WR key The designated bit data reverses 0 to 1 or 1 to 0 If you depress the WR key...

Page 18: ...SETTING DATA of YASNAC MX 2 OPERATOR S MANUAL TOE C843 8 30 See 4 3 6 DISPLAYING AND 1 On 0 Off 7 6 5 4 3 2 1 0 3 Writing parameters 0 0 6001 1 The parameter values are preset according to the perform...

Page 19: ...coincides with the data character string entered through the NC operator s panel is found The contents of tape will be searched in TAPE mode and those of the part program memory in MEM or EDIT mode 1...

Page 20: ...0 means that no break point is designated Sequence number of up to 4 digits without address N Leading zeros may be omitted Commands encountered during search will be ignored even if they are modal com...

Page 21: ...will be displayed on the CRT This is possible at any time even dur ing automatic operation For more detail of this operation see 8 6 3 DIAGNOSTICS OF INPUT OUTPUT SIGNALS of YASNAC MX 2 OPERATOR S MAN...

Page 22: ...ion is as follows A Select EDIT mode B Depress the RESET key C Deprss the PRM key D Set the setting parameter data tape onto the tape reader E Depress IN key The tape reader starts to read the tape IN...

Page 23: ...During the output of data OUT is flashing 2 Punch out of all part programs All registered part programs may be output to the external equipment by the above operations except that 0 9 9 9 9 must be ke...

Page 24: ...duplicat of the program number as in 1 Operation ends with error if the designated program number is not found on the tape When the tape reader has read M02 M03 or M99 appears from the CRT Now the pa...

Page 25: ...m number punched on the tape is stored in the part program memory without change Consequently to avoid the confusion in the later handling replace the program number in the part program memory with ch...

Page 26: ...y be keyed in over multiple words or blocks However when the 10th character is keyed in the normal display shown to the right of the line is blanked e i 2 All program numbers already registered are di...

Page 27: ...er The display will be reset by depressing the CAN key 01234 N100 X5 0 V 100 N101 G01 Z 10 N102 X 30 Y 50 F200 N103 X 50 N104 Y 10 LSK RDY 1 INS f AL T I N 01234 N1000 PROGRAM EDI T 01234 N001 G92 X0...

Page 28: ...e 01234 N1000 pvotiwnri f I I Word Modification Specify the word to be altered with the CURSOR key in the new word and depress the ALTER key The new word will replace the CURSOR mdicated word Before M...

Page 29: ...interface Equipment having RS232C interface Equipment having RS422 interface Functions Output the NC data to the ex ternal equipment for punching out NC tape Storing NC data into NC memory or collatin...

Page 30: ...32C Interface As shown below the data is set for input and output combined or separately 6028 D6 0 Data is set for input and output combined 1 Data is set for input and output separately 6028D5 Output...

Page 31: ...lled control codes If the specifications of the input output equipment do not allow the ac ceptance of the control codes set the para meter for control code transmission designation to 1 not send In t...

Page 32: ...ARM o J 20 Note 2 L25 Not used Notes 1 The type of connector and pm number are different with external equipment 2 When the current loop interface is used short circuit pm No 4 signal RS and pm No 5 s...

Page 33: ...terface allows the following operations and runs Signal grounding SG 19 1 The input output operations of tool offset amounts setting data and parameter data and the output operations punch out of part...

Page 34: ...3 2 4 Depress RESET key Verifying a part program tape having no program number Load the NC tape via tape reader 5 Select the EDIT mode a 6 Depress VER key Tape starts and the contents of tape and the...

Page 35: ...r Hence when verifying a tape containing program numbers no program number should be keyed in b Depress the PROG function key c Set the part program tape to the tape read er d Depress the RESET key e...

Page 36: ...program O Match ing with tape I RESET I Ipl number VER Tape without number O Note I Program c v GO All part programs on tape RESET VER o CL CURSOR Set to address data to be modified Address data j AL...

Page 37: ...ackward 3 PRM J CURSOR CURSOR SET 0 Cursor forward Setting X SET g COM o 3 HOME ORG j COM Command Home key PROG 0 0 S H Program Address PROG 0 0 Slash Position POS 0 0 0 Offset End of block OFS 3 X B...

Page 38: ...oad Sec 2 Taipei Taiwan Phone 2 531 7732 551 7065 Fax 2 537 3837 YASKAWA ELECTRIC AMERICA INC SUBSIDIARY Chicago Office YASNAC America 3160 MacArthur Bivd Northbrook Illinois 60062 USA Phone 312 291 2...

Reviews: