![YASKAWA SI-ET3 Technical Manual Download Page 41](http://html1.mh-extra.com/html/yaskawa/si-et3/si-et3_technical-manual_3272479041.webp)
YASKAWA
SIEP C730600 88F MECHATROLINK-III Technical Manual
41
■
INVCMD_STAT
Vendor Specific
bit1
bit0
bit7
bit6
bit5
bit4
bit3
bit2
oPE Error
Drive Ready
Speed Agree
Zero speed
Main Power Supply
ON
Baseblock Released
Reverse Operation
Forward Operation
Vendor Specific
bit9
bit8
bit15
bit14
bit13
bit12
bit11
bit10
Not used
Zero Servo
Motor 2 Selection
LOCAL/REMOTE
Power Loss
Recovery/
Momentary Power
Loss Recovery
Fault Reset Signal
being Input
Reserved (0)
Vendor Specific
bit23
bit22
bit21
bit20
bit19
bit18
bit17
bit16
Not used
bit31
bit30
bit29
bit28
bit27
bit26
bit25
bit24
Reserved (0)
SEL_MON2
Status
SEL_MON1
Status
Table 9.9 INVCMD_STAT Bits
Bit
Name
Description
0
Forward Operation
0: Stop
1: Forward operation in progress
1
Reverse Operation
0: Stop
1: Reverse operation
2
Baseblock Released
0: Baseblock
1: Baseblock released
3
Main Power Supply ON
0: Main power supply OFF
1: Main power supply ON
4
Zero Speed
1: Zero Speed
5
Speed Agree
1: Speed agree
6
Drive Ready
1: Drive ready
7
oPE Error
1: oPE error
9
Fault Reset Signal being Input
1: Fault reset signal being input
10
Power Loss Recovery/Momentary
Power Loss Recovery
0: Power loss recovery
1: Momentary power loss recovery
11
LOCAL/REMOTE
0: LOCAL
1: REMOTE
12
Motor 2 Selection
0: Motor 1
1: Motor 2
13
Zero Servo
1: Zero servo
24
SEL_MON1 Status
0: Disabled
1: SEL_MON1 enabled
25
SEL_MON2 Status
0: Disabled
1: SEL_MON2 enabled
■
INVCMD_IO Response
Vendor Specific
bit7
bit6
bit5
bit4
bit3
bit2
bit1
bit0
Not used
Vendor Specific
bit15
bit14
bit13
bit12
bit11
bit10
bit9
bit8
Not used