50
YASKAWA
TOEP C730600 89B PROFINET Installation Manual
Bit
Name
Value
Proceed to STATE/Description
0
Halt ramping (Ramp Function Generator output held). Proceed to
RAMP FUNCTION GENERATOR: ENABLE ACCELERATOR.
6
RAMP_IN_ZERO
1
Normal operation. Proceed to OPERATING.
Note:
This bit is effective only if the fieldbus interface is set as the
source for this signal by drive parameters.
0
Force Ramp Function Generator input to zero.
7
RESET
0 -> 1
Fault reset if an active fault exists. Proceed to SWITCH ON
INHIBIT.
0
(Continue normal operation)
8
INCHING_1
-
Inching 1. (Not supported)
9
INCHING_2
-
Inching 2. (Not supported)
10
REMOTE_CMD
1
Network control enabled.
0
Network control disabled.
11 - 15
-
-
Reserved
0
RDY_ON
1
READY TO SWITCH ON.
0
NOT READY TO SWITCH ON.
1
RDY_RUN
1
READY TO OPERATE.
0
OFF1 ACTIVE.
2
RDY_REF
1
ENABLE OPERATION.
0
DISABLE OPERATION.
3
TRIPPED
1
FAULT.
0
No fault.
4
OFF_2_STA
1
OFF2 inactive.
0
OFF2 ACTIVE.
5
OFF_3_STA
1
OFF3 inactive.
0
OFF3 ACTIVE.
6
SWC_ON_INHIB
1
SWITCH-ON INHIBIT ACTIVE.
0
SWITCH-ON INHIBIT NOT ACTIVE.