Document Title:  Tech Guide ~ Yaskawa V1000 Basic User Guide 

Common Drive Monitors

Note:  these are basic tips, refer to the technical manual for more information

U1-01

Frequency Reference Monitors the frequency 

U1-02

Output Frequency Displays the output frequency. Display units are determined by o1-03.

U1-03

 Output Current Displays the output current. 

U1-04

 Control Mode Control method set in A1-02.

U1-05

 Motor Speed Displays the motor speed feedback. Display units are determined by o1-03.

U1-06

 Output Voltage Reference Displays the output voltage. 

U1-07

 DC Bus Voltage Displays the DC bus voltage. 

U1-08

 Output Power Displays the output voltage (this value is determined internally).

U1-13

 Terminal A1 Input Level Displays analog input A1 level: 100% when input is 10 V.

U1-14

 Terminal A2 Input Level Displays analog input A1 level: 100% when input is 10 V.

U3-01

 Most Recent Fault Displays the most recent fault.

U3-02

 2nd Most Recent Fault Displays the second most recent fault. 

U3-03

 3rd Most Recent Fault Displays the third most recent fault. 

U3-04

 4th Most Recent Fault Displays the fourth most recent fault.

U3-05

 5th Most Recent Fault Displays the fifth most recent fault. 

U3-06

 6th Most Recent Fault Displays the sixth most recent fault.

U3-07

 7th Most Recent Fault Displays the seventh most recent fault. 

U3-08

8th Most Recent Fault Displays the eighth most recent fault. 

U3-09

 9th Most Recent Fault Displays the ninth most recent fault.

U3-10

 10th Most Recent Fault Displays the tenth most recent fault.

U4-01

 Accumulated Operation Time Displays the cumulative operation time of the drive.

U4-02

 Number of Run Commands Displays the number of times the run command is entered.

Summary of Contents for PROFINET V1000

Page 1: ...Document Revision v1 0 5 of 1 10 page 18805 Adams Ct 110 Morgan Hill CA 95037 USA 1 408 924 0808 www washlinksystems com support washlinksystems com Tech Guide Yaskawa V1000 Basic User Guide ...

Page 2: ..._____________________________ Contact Person ______________________________ Contact Phone ______________________________ VFD Model ______________________________ Equipment connected ______________________________ Distributor Name ______________________________ COPYRIGHT 2013 Washlink Systems All rights reserved THIS DOCUMENT IS THE EXCLUSIVE PROPERTY OF WASHLINK SYSTEMS AND IS PREPARED ONLY FOR US...

Page 3: ...t Current Amps Output Voltage Monitor Display typically not used Verify Menu typically not used Set Up Mode typically not used Parameter Setting mode Auto Tuning Hz drive set to run Forward Selection Reverse Selection typically not used Standard Operator Panel Display To Change Display Data View The standard screen after a power cycle is the actual output in Hz xx xx To change data being displayed...

Page 4: ...ameter A1 02 with the A flashing ENTER Press the or or to get to the parameter you want to adjust then press ENTER RESET You will now see the current setting for the selected parameter left digit will flashing Press the or or to change the parameter then press ENTER RESET With the VFD powered on and the motor not running You will now see the next parameter with the left digit flashing 1 2 3 4 5 6 ...

Page 5: ...econds If used typically between 1 0 3 0 note if more then one motor on same sensor times must be different to prevent drive speed bouncing C1 01 Acceleration time 1 in seconds Typically between 3 0 15 0 C1 02 Deceleration time 1 in seconds Typically between 3 0 25 0 d1 01 Frequency Reference 1 speed in Hz Typically between 35 0 60 0 d1 02 Frequency Reference 2 speed in Hz Typically between 35 0 6...

Page 6: ...termined internally U1 13 Terminal A1 Input Level Displays analog input A1 level 100 when input is 10 V U1 14 Terminal A2 Input Level Displays analog input A1 level 100 when input is 10 V U3 01 Most Recent Fault Displays the most recent fault U3 02 2nd Most Recent Fault Displays the second most recent fault U3 03 3rd Most Recent Fault Displays the third most recent fault U3 04 4th Most Recent Faul...

Page 7: ...s damaged Check the insulation resistance Replace the motor One of the motor cables has shorted out or there is a grounding problem Check the motor cables Check the resistance between the motor cables and the ground terminal Replace damaged cables The load is too heavy Reduce the load to avoid sudden changes in the current level or switch to a larger drive The acceleration or deceleration times ar...

Page 8: ...t power Check for wiring errors in the main circuit drive input power There is loose wiring in the drive input power terminals Ensure the terminals are tightened properly There is excessive fluctuation in the drive input voltage Check the voltage from the drive input power There is poor balance between voltage phases Stabilize drive input power or disable phase loss detection Over Voltage Decelera...

Page 9: ...t 110 Morgan Hill CA 95037 USA 1 408 924 0808 www washlinksystems com support washlinksystems com Document Title Tech Guide Yaskawa V1000 Basic User Guide Revision history v1 0 1 Initial release v1 0 3 Various typo s v1 0 5 Fixed red display box images ...

Page 10: ...ent Revision v1 0 5 of 10 10 page 18805 Adams Ct 110 Morgan Hill CA 95037 USA 1 408 924 0808 www washlinksystems com support washlinksystems com Document Title Tech Guide Yaskawa V1000 Basic User Guide Notes ...

Reviews: