5-7 Address Setting
5
−
55
Builder
Chapter 5 Operating Objects
Number Item
Contents
1) Address
Setting
Specifies the address. If an invalid address is input, a message,
starting that the address is invalid, is displayed after [OK] is
clicked.
Specifies an index for the specified address. Addresses can
automatically be allocated by adding the value of the index to the
address.
10 types of indexes (“I0” to “I9”) are available.
The value of the address or any number can be specified for the
index value.
y
Example
Address: CB0I0
If I0 = 10, then the address is CB10.
If I0 = 20, then the address is CB20.
The address used for the communication automatically changes by
the value of I0.
I0 Value
Address
0 CB0
1 CB1
2 CB2
xxx
xxx
2)
Index
Specification