4
I/O Signal Allocation
4.2
Transmission Data
4-27
HW1484564
HW1484564
[INpact/AB3602 Board Status]
The status of the INpact/AB3602 board (the first 8 points of the allocation
area) is indicated as follows.
The value “xxx” of the allocated input signals in the table indicates the first
number of the INpact/AB3602 board allocated number. In the table
above, where the allocation numbers are 20020 to 20027, “xxx” would be
“002”.
AB3602
(Profibus)
I/O Output
30080 to 30087
10080 to 10087 (OT0057 to OT0064)
Output data (6)
30090 to 30097
10090 to 10097 (OT0065 to OT0072)
Output data (7)
30100 to 30107
10100 to 10107 (OT0073 to OT0080)
Output data (8)
30110 to 30117
10110 to 10117 (OT0081 to OT0088)
Output data (9)
30120 to 30127
10120 to 10127 (OT0089 to OT0096)
Output data (10)
30130 to 30137
10130 to 10137 (OT0097 to OT0104)
Output data (11)
30140 to 30147
10140 to 10147 (OT0105 to OT0112)
Output data (12)
30150 to 30157
10150 to 10157 (OT0113 to OT0120)
Output data (13)
30160 to 30167
10160 to 10167 (OT0121 to OT0128)
Output data (14)
30170 to 30177
10170 to 10177 (OT0129 to OT0136)
Output data (15)
30180 to 30187
10180 to 10187 (OT0137 to OT0144)
Output data (16)
1 Board status and system reservation cannot be allocated as IO signal.
Also, this data is not able to transmit by Profibus.
(Unable to communicate with the main PLC.)
Signal
Contents
2xxx0 to 2xxx4
Reserved for the manufacture. The user cannot use these signals.
2xxx5
INpact
Not used
Always set to 0.
AB3602
Indicates if communicating with all the slaves or not through Profibus.
Communicating with all slaves: 0
Communicating with some slaves: 1
2xxx6
Indicates the Profibus communication status.
Normal: 0 Error: 1
2xxx7
Indicates the operation status of the INpact/AB3602 board.
Normal: 0 Error: 1
47/60