4
I/O Signal Allocation
4.1
Setting of Option Board and I/O Module
4-14
HW1484564
HW1484564
6. Select “AB3602”.
– The AB3602 setup display appears.
– Set the following items without fail:
• “AB3602”: whether to use the AB3602 board or not
• “IO SIZE”: the I/O size (byte)
• “NODE ADDRESS”
• “BAUD RATE”
• As for SCAN LIST, refer to the following step 7 to step 11.
For the settings other than mentioned above, execute settings
as the need arises.
– Explanation of Setup Items
(1) AB3602
Sets whether to use the AB3602 board or not.
Set “USED”.
(2) IO SIZE (byte)
Sets the I/O size (in bytes) reserved for I/O.
The maximum setting value of the I/O size is 255 bytes.
(3) NODE ADDRESS
It cannot be set with this window but set by Anybus NetTool for
PROFIBUS.
(4) BAUD RATE
It cannot be set with this window but set by Anybus NetTool for
PROFIBUS.
(1)
(2)
(3)
(4)
34/60