A-1
151521-1CD
151521-1CD
Appendix A
Options Installation
A.1
Installing the Over Travel Limit Switch
To install the over travel limit switch option, proceed as follows:
1.
Mount limit switch actuators in desired locations along the limit switch diameter of the
customer supplied adapter plate using M16x70 hardware provided.
Fig. A-1 Hard Stop Installation
2.
Mount limit switch brackets to the top of the drive assembly mounting plate using the M6x20
hardware provided.
Fig. A-2 Limit Switch Mounting Locations
When properly installed, the over-travel limit switches provide overtravel electrical signals to the
controller. The limit switches are not designed as physical limits or hard stops.
LIMIT SWITCH DIAMETER
CUSTOMER SUPPLIED
ADAPTER PLATE
LIMIT SWITCH
ACTUATORS
M16X70 SCREW
WARNING
37 of 47