4.6 Setup Procedure for Elevator Applications
• Inspection Operation
■ Start Condition in Inspection Operation
N O TIC E:
A lw a y s turn o ff the R U N c o m m a n d b e fo re c h a n g in g the s e ttin g o f p a ra m e te rs d 1 -1 8 (S p e e d R e fe re n c e S ele ctio n M ode), b1-
01 (S p e e d R e fe re n ce S election), o r
Н 1 - П П
(M u lti-F u n c tio n D ig ita l Inputs). I f the R U N c o m m a n d is on w h en c h a n g in g a n y o f these
settings, the m o to r m a y u n e x p e c te d ly start running, a n d c o u ld re s u lt in injury.
Inspection operation is performed when an Up or Down signal is input while one of the following conditions is true:
• Parameter d1-18 is set to 0 or 3 and the selected speed is higher than d1-28 but lower than d1-29.
• Parameter d1-18 is set to 1 or 2 and a digital input programmed for Inspection Operation Speed (И1-ПП = 54) is
enabled.
Inspection Operation uses the same acceleration characteristics and brake sequence at start as normal operation.
The carrier frequency is set to 2 kHz during Inspection Operation, but can be changed using parameter C6-21.
■ Stop Condition in Inspection Operation
To stop the drive during Inspection Operation, either remove the Up or Down command or reset the input terminal for
Inspection Operation.
A deceleration ramp can be set for Inspection Operation using parameter C1-15.
• If C1-15 = 0.00, the drive immediately applies the brake, shuts off the drive output, and opens the motor contactor, i.e.,
the multi-function output terminals set for “Brake Control” (H 2-DD = 50) and “Output Contactor Control” (H2-DD =
51) are cleared.
• If C1-15 > 0.00, the drive decelerates to stop at the rate set to C1-15, then applies the brake, shuts the output off, and
opens the motor contactor.
■ Inspection Operation Timing Chart
A timing chart for Inspection Operation appears in
Figure 4.14.
Inspection O peration w ithout Decel Ramp (C1-15=0)
Inspection Operation
Speed
Safe disable (terminals H1/H2 on)
and Baseblock off (H1-DD=8/9)
H1-DD = 54 (Inspection Operation)
Up/Down command
H2-DD = 51 (Output Cont. Contr.)
H2-DD = 50 (Brake Control)
Inspection O peration with Decel Ramp (C1-15>0)
Inspection Operation
Speed
D C Injectio n B ra king /
P osition L ock at s ta rt /
C 1-15
Speed
Safe disable (terminals H1/H2 on)
and Baseblock off (H1-DD=8/9)
H1-DD = 54 (Inspection Operation)
Up/Down command
H2-DD = 51 (Output Cont. Contr.)
H2-DD = 50 (Brake Control)
<1> The drive stops if either the U p/D own comm and or Inspection O peration signals are removed.
F ig u r e 4 .1 4 I n s p e c tio n O p e r a tio n S e q u e n c e