5 Related Parameters
5
Related Parameters
The following parameters are used to set up the drive for operation with an option card.
Set parameters as needed. Instructions on how to set parameters can be found in the
instruction manual for the drive the option card is connected to.
Table 5 Related Parameters
No.
<1> Binary input is not possible if o1-03 is set to 2 or 3. The setting of F3-01 will be disregarded and setting units
will be determined by o1-03.
<1>
Parameter Name
Description
Setting
Range
Default
F3-01
<1>
Option Card Input
Selection
Selects the method to input the option card data.
0: BCD 1% unit
1: BCD 0.1% unit
2: BCD 0.01% unit
3: BCD 1 Hz unit
4: BCD 0.1Hz unit
5: BCD 0.01Hz unit
6: BCD custom setting (5 digit input), 0.02 Hz units
7: Binary input
0 to 7
0
F3-03
Data Length
Selection
0: 8 bit
1: 12 bit
2: 16 bit
0 to 2
2