The table below lists the messages and errors that may appear when using the Copy function. When executing the tasks
offered by the Copy function, the operator will indicate the task being performed. When an error occurs, a code appears
on the operator to indicate the error. Note that errors related to the Copy function do not trigger a multifunction output
terminal that has been set up to close when a fault or alarm occurs. To clear an error, simply press any key on the operator
and the error display will disappear.
lists the corrective action that can be taken when an error occurs.
Note: 1.
Whenever using the copy function, the converter should be fully stopped.
2.
The converter will not accept a Run command while the Copy function is being executed.
3.
Parameters can only be saved to a converter when the voltage class, capacity, control mode, and software version match.
Table 5.9 Copy Function Task and Error Displays
Digital Operator Display
Error Name
CoPy
Writing Parameter Settings (flashing)
CPyE
Error Writing Data
CSEr
Copy Unit Error
dFPS
Converter Model Mismatch
End
Task Complete
iFEr
Communication Error
ndAT
Model, Voltage Class, Capacity Mismatch
rdEr
Error Reading Data
rEAd
Reading Parameter Settings (flashing)
vAEr
Voltage Class, Capacity Mismatch
vFyE
Parameter settings in the converter and those saved to the copy function are not the same
vrFy
Comparing Parameter Settings (flashing)