10.18 Parameters that Change from the Default Settings with E3-01 [Motor 2 Control Mode Selection]
554
YASKAWA
SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
10.18 Parameters that Change from the Default Settings with
E3-01 [Motor 2 Control Mode Selection]
The values for the parameters in these tables depend on the values for parameter
E3-01
. When you change
E3-01
,
the default settings will change.
No.
Name
Range
Unit
Motor 2 Control Method (setting value of E3-01)
V/f
(0)
CL-V/f
(1)
OLV
(2)
CLV
(3)
C3-21
Motor 2 Slip
Compensation Gain
0.0 - 2.50
0.1
0.0
-
1.0
1.0
C3-22
Motor 2 Slip Comp
Delay Time
0 - 10000
1 ms
2000
-
200
-
C4-08
M2 Torque Comp Delay
Time
0 - 60000
1 ms
200
200
20
-
C4-14
M2 Torque Comp Delay
Time Sel 1
0 - 60000
1 ms
200
200
20
-
C5-21
Motor 2 ASR
Proportional Gain 1 (P)
0.00 - 300.00
0.01
-
0.20
-
20.00
C5-22
Motor 2 ASR Integral
Time 1 (I)
0.000 - 10.000
0.001 s
-
0.200
-
0.500
C5-23
Motor 2 ASR
Proportional Gain 2 (P)
0.00 - 300.00
0.01
-
0.02
-
20.00
C5-24
Motor 2 ASR Integral
Time 2 (I)
0.000 - 10.000
0.001 s
-
0.050
-
0.500
C5-26
Motor 2 ASR Delay
Time
0.000 - 0.500
0.001 s
-
-
-
0.004
E3-04
Motor 2 Maximum
Output Frequency
40.0 - 590.0
0.1 Hz
50.0
50.0
50.0
50.0
E3-05
Motor 2 Maximum
Output Voltage
0.0 - 255.0
0.1 V
200.0
200.0
200.0
200.0
E3-06
Motor 2 Base Frequency
0.0 - 590.0
0.1 Hz
50.0
50.0
50.0
50.0
E3-07
Motor 2 Mid Point A
Frequency
0.0 - 590.0
0.1 Hz
2.5
2.5
3.0
-
E3-08
Motor 2 Mid Point A
Voltage
0.0 - 255.0
0.1 V
15.0
15.0
14.4
-
E3-09
Motor 2 Minimum
Output Frequency
0.0 - 590.0
0.1 Hz
1.3
1.3
0.5
0.0
E3-10
Motor 2 Minimum
Output Voltage
0.0 - 255.0
0.1 V
9.0
9.0
3.0
-
E3-11
Motor 2 Mid Point B
Frequency
0.0 - 590.0
Determined by
o1-04
0.0
0.0
0.0
0.0
E3-12
Motor 2 Mid Point B
Voltage
0.0 - 255.0
0.1 V
0.0
0.0
0.0
0.0
E3-13
Motor 2 Base Voltage
0.0 - 255.0
0.1 V
0.0
0.0
0.0
0.0
E3-14
M2 Middle Out Freq Volt
Select
0.0 - 255.0
0.1 V
15.0
15.0
14.4
-
E3-15
M2 Minimum Out Freq
Volt Select
0.0 - 255.0
0.1 V
9.0
9.0
3.0
-
S1-25
Motor2 Brake Delay
Frequency
0.0 - 400.0
0.1 Hz
3.0
3.0
3.0
0.0
S1-26
Motor2 Brake Delay
Time
0.00 - 10.00
0.01 s
0.30
0.30
0.30
0.00
S1-31
Motor2 Torque
Compensation (FWD)
-200 - +200
1%
-
-
50
0
S1-36
Motor2 Slip Prevention
Frequency
0.0 - 20.0
0.1 Hz
3.0
3.0
3.0
0.0
S1-37
Motor2 Slip Prevention
Time
0.00 - 10.00
0.01 s
0.30
0.30
0.30
0.00
*1
This is the value for 200 V class drives. Double the value for 400 V class drives.
Summary of Contents for CR700
Page 1: ......
Page 244: ...3 13 Test Run Checklist 244 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 422: ...7 7 Storage Guidelines 422 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 426: ...8 2 Disposal Instructions 426 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual ...
Page 837: ...EZZ023535 2 35 1 Revision History Revision Revised Content Date First Edition 2017 08 ...
Page 872: ...EZZ023536 2 16 Revision History Revision Revised Content Date First Edition 2017 08 ...