background image

Displays the 

Super I/O Chip

 used on the board.

This section is used to configure serial port 1.

Super IO Chip

Submenu "Serial Port 1

Configuration"

HMI

BIOS setup

Advanced 

HB160 | PPC | 67S-RRJ0 | en | 23-10

 

44

Summary of Contents for 67S-PNJ0-EB

Page 1: ...PPC 67S RRJ0 Manual HB160 PPC 67S RRJ0 en 23 10 HMI Panel PC PPC021 EC...

Page 2: ...67S RRJ0_000_PPC021EC 4 EN 2023 YASKAWA Europe GmbH Philipp Reis Str 6 65795 Hattersheim Germany Tel 49 6196 569 300 Fax 49 6196 569 398 Email info yaskawa eu Internet www yaskawa eu com...

Page 3: ...3 5 Operating system Windows Embedded Compact 7 30 3 5 1 General 30 3 5 2 Structure 31 3 6 Integrated server 33 3 6 1 General 33 3 6 2 ftp server 34 3 6 3 Telnet server 35 3 6 4 VNC server 36 3 7 Acc...

Page 4: ...ecial precautions providing high noise immunity 70 5 2 5 Checklist for the EMC compliant installation of controllers 71 Appendix 72 A History of changes 74 HMI Table of contents HB160 PPC 67S RRJ0 en...

Page 5: ...that the information contained in this document was complete and accurate at the time of publishing We cannot guarantee that the infor mation is free of errors and we reserve the right to change the i...

Page 6: ...t passages in the text are highlighted by following icons and headings DANGER Immediate or likely danger Personal injury is possible CAUTION Damages to property is likely if these warnings are not hee...

Page 7: ...dware modifications to the process control system should only be carried out when the system has been disconnected from power Installation and hardware modifications only by properly trained per sonne...

Page 8: ...odules that have been damaged by electrostatic discharges can fail after a temperature change mechanical shock or changes in the electrical load Only the consequent implementation of protection device...

Page 9: ...P multitouch n Display resolution 1920 x 1080 n Processor Baytrail Intel Celeron J1900 Quad core 2GHz n Work memory 2x 204Pin DDR3 SO DIMM Socket 2GB DDR3 n User memory 2GB SATA DOM n CFast slot n 2 R...

Page 10: ...SB 3 0 7 2x USB A interface USB 2 0 8 RJ45 jack for Ethernet communication LAN 2 9 RJ45 jack for Ethernet communication LAN 1 10 2 pin connector for remote Power switch 11 3 5mm Audio Line out 12 Powe...

Page 11: ...ch 11 3 5mm Audio Line out Please make sure that the Panel PC always has to be supplied with external voltage 1 Slot for CFast storage media 2 Power switch pushbutton The Panel PC starts automatically...

Page 12: ...d an according DC 24V slot at the back The power supply is protected against inverse polarity and overcurrent The matching 3 pin plug con nector is included in the scope of delivery VGA SubD HD15 jack...

Page 13: ...kbit s RS422 interface n Logical conditions as voltage difference between 2 twisted lines n Serial bus connection full duplex four wire operation n Line length 250m at 115 2kbit s 1200m at 19 2kbit s...

Page 14: ...HMI Hardware description Structure Interfaces HB160 PPC 67S RRJ0 en 23 10 14...

Page 15: ...twisted pair cable required for Ethernet LEDs Activity yellow Link green Link orange Description blinks 1000Mbit s link blinks 100Mbit s link blinks 10Mbit s link or no link not active At this connect...

Page 16: ...are supported by the Panel PC At the back of the Panel PC there is a card slot for a memory card At this slot you can plug storage modules of the type CFast 2 0 600 MB s 6GBit s SATA protocol not hot...

Page 17: ...W x H x D 542 x 362 x 54 2mm Installation depth 54 2mm The degrees of protection are only guaranteed when the following is observed The material thickness of the installation cut out is 3 12mm The de...

Page 18: ...reference earth Inputs outputs AC DC 50V test voltage AC 500V Protective measures against short circuit Environmental conditions to EN 61131 2 Climatic Storage transport EN 60068 2 14 20 75 C Operati...

Page 19: ...e external protective circuit with lightning protection elements like conductors for lightning and overvoltage is necessary 2 6 Use in difficult operating conditions Without additional protective meas...

Page 20: ...Accuracy max deviation per day 10 s Operating controls Touchscreen PCAP Touch function Dual Touch Keyboard external via USB Mouse external via USB Interfaces MPI PROFIBUS DP MPI PROFIBUS DP connector...

Page 21: ...al data Housing Protection class Material coated aluminium steel plate Mounting via integrated pivoted lever Protection class IP front side IP 66 Protection class IP back side IP 20 Protection class N...

Page 22: ...Order no 67S RRJ0 EB Certifications UL certification yes KC certification HMI Hardware description Technical data HB160 PPC 67S RRJ0 en 23 10 22...

Page 23: ...ting tableau and control cabinet fronts the Panel PC requires the following front panel cutting Panel PC W x H in mm 67S RRJ0 547 x 367mm The material thickness of the installation cut out is 3 12mm F...

Page 24: ...pulling the plate 2 With the label facing up insert the CFast card until it is completely seated in the slot and reinstall the cover plate After installation the CFast card is automatically recognize...

Page 25: ...ON When changing the Regional Settings please note that only English and German are supported other languages can lead to a system crash 3 3 1 Firmware update To execute the firmware update an externa...

Page 26: ...y default no password is defined In Settings the system settings can be set exactly like via Windows Start Settings Control Panel n To execute the firmware update press the button Info Update After cl...

Page 27: ...ttons and 5 seconds are default n Via Program start with you can add programmes which have to start automati cally n Via Rotation the orientation of the panel can be changed 1 Select start and assign...

Page 28: ...light the local settings and the LAN settings will be saved by Backup in Flashdisk Backup The name of the backup file is backup bkv Which settings will be saved and the storage location are defined i...

Page 29: ...lled runtime version of the HMI SCADA project engineering platforms your project is run able n By using the according communication driver the Panel PC supports connecting options to the PLC via Ether...

Page 30: ...twice A double click on an object opens res executes this n Drag By tapping on an object and then dragging you can move the object on the screen If no object is selected a frame is created by the dra...

Page 31: ...ou access to all components of your Panel PC such as appli cations system settings file browser etc 2 Open applications For every open application a button can be found in the task bar There is no but...

Page 32: ...s Lock The software keyboard allows you to enter key entries without connecting an external keyboard As soon as an entry is required the software keyboard is automatically shown Hide Input Panel hides...

Page 33: ...date time numbers and other formatting CAUTION When changing the Regional Settings please note that only English and German are supported other languages can lead to a system crash 3 6 Integrated serv...

Page 34: ...justment choose in the Internet Explorer Options Internet options register extended in the area Browsing and set the following settings 1 activate activate directory view for ftp sites 2 Restart the I...

Page 35: ...protected and has the following approach 1 Start a Telnet client like for example MS DOS console at your PC and enter the following into the address bar telnet IP address When the connection is establ...

Page 36: ...deactivate all safety attitudes with the VNC server you should use these exclusively for start up For this reason the VNC server is on delivery deactivated Due to software reasons Yaskawa does not su...

Page 37: ...word vipatp You can change the password over the configuration file for this execute vncconfig exe Now a VNC connection is established and the screen con tent of the Panel PC is monitored within a win...

Page 38: ...etwork PC The connection of a local name at the Panel PC with a shared drive of the network PC happens with the following approach 1 Enter the following in the command prompt net use local_name networ...

Page 39: ...s n Making changes to the power management configuration n Changing the password or making other changes to the security setup Normally CMOS setup is needed when the system hardware is not consistent...

Page 40: ...Saves and exits the setup program Enter Enters the highlighted submenu When 4 appears on the left of a particular field it indicates that a submenu which contains addi tional options are available fo...

Page 41: ...format is hour minute second n hour displays hours from 00 to 23 n minute displays minutes from 00 to 59 n second displays seconds from 00 to 59 4 3 Advanced This menu allows you to configure the syst...

Page 42: ...This section is used to configure Advanced Configuration and Power Interface ACPI Settings Submenu ACPI Settings HMI BIOS setup Advanced HB160 PPC 67S RRJ0 en 23 10 42...

Page 43: ...when the suspend button is pressed Suspend Disabled Sleep state disabled S3 Suspend to RAM Standby mode enabled Windows saves the system state in RAM This section is used to configure serial ports En...

Page 44: ...Displays the Super I O Chip used on the board This section is used to configure serial port 1 Super IO Chip Submenu Serial Port 1 Configuration HMI BIOS setup Advanced HB160 PPC 67S RRJ0 en 23 10 44...

Page 45: ...resistor Disabled Terminal resistor not activated Enabled default Terminal resistor activated This section is used to configure serial port 2 Enables or disables the serial port Disabled Serial port...

Page 46: ...Terminal resistor not activated Enabled default Terminal resistor activated This section Pc Health Status is used to configure the hardware temperature and vol tages This section is used to configure...

Page 47: ...unctions are supported Enabled Limit the return value to 3 or less than 3 XD can prevent certain classes of malicious buffer overflow attacks Enabled Permit the switching on of the execute disable fun...

Page 48: ...This section is used to configure the Processor Power Management PPM configuration Submenu PPM Configu ration HMI BIOS setup Advanced HB160 PPC 67S RRJ0 en 23 10 48...

Page 49: ...to use AHCI Advanced Host Con troller Interface AHCI allows the storage driver to enable the advanced serial ATA features which will increase storage performance Enables or disables SATA port 0 Enabl...

Page 50: ...pplications Enabled Default Enables USB 3 0 controller support Disabled Disables USB 3 0 controller support Enabled Enables XHCI USB 3 0 or EHCI USB 2 0 support Disabled Disables XHCI USB 3 0 or EHCI...

Page 51: ...this option only when changing the panel otherwise the display may not work The options are Tact Switch Manual and Light Sensor The default setting is Manual and the Backlight option below will be co...

Page 52: ...te where you left off before power failure occurs Power Off The system s power is off You must press the power button to Power On the system Power On default The system will automatically Power On Thi...

Page 53: ...e Disabled Azalia will be unconditionally disabled Enabled Azalia will be unconditionally enabled Enables or disables internal HDMI Codec for Azalia Audio Controller Azalia HDMI Codec HMI BIOS setup C...

Page 54: ...e EHCI con troller must always be enabled Enables or disables PCH USB rate matching hubs mode Enables or disables PCH EHCI debug capability Submenu USB Configura tion USB 2 0 EHCI Support USB RMH Mode...

Page 55: ...Enables or disables the PCI Express ports 0 3 on the chipset Submenu PCI Express Configuration PCI Express Port 0 PCI Express Port 3 HMI BIOS setup Chipset HB160 PPC 67S RRJ0 en 23 10 55...

Page 56: ...ll decrease the time needed to boot the system Controls the execution of UEFI and legacy PXE OpROM Enables or disables the boot option for legacy network devices connected to LAN1 or LAN2 Disabled def...

Page 57: ...when entering setup If only the User s password is set then this is a power on password and must be entered to boot or enter setup In Setup the user will have administrator rights If ONLY the Adminis...

Page 58: ...east 3 characters and should be maximal 20 characters long Select this to reconfigure the user s password Your password must contain at least 3 characters and should be maximal 20 characters long Admi...

Page 59: ...nfirm again before exiting The BIOS setup exits and a restart follows To restore the BIOS to default settings select this field then press Enter A dialog box will appear Confirm by selecting Yes To sa...

Page 60: ...rd phishing The most important precautions to prevent manipulation and loss of data security in the industrial environment are n Encrypting the data traffic by means of certificates n Filtering and in...

Page 61: ...he communication ports that are used for communication should be acti vated Only the communication protocols that are used for communication should be activated n Consider possible defence strategies...

Page 62: ...ected against manipulation n Use encryption systems on your storage media n Perform security assessments regularly to reduce the risk of manipulation n Use only data and software from approved sources...

Page 63: ...use Typical source Galvanic coupling Galvanic or metallic coupling always occurs when two current circuits have a common line n Pulsed devices Net influence from transducers and foreign net devices n...

Page 64: ...extensive and impedance low Please try not to use aluminium parts Aluminium is easily oxidizing and is there fore less suitable for grounding n When cabling take care of the correct line routing Organ...

Page 65: ...ing actions The grounding of the PLC serves for protection and functionality activity Connect installation parts and cabinets with your PLC in star topology with the isolation protected earth conducto...

Page 66: ...an error Thus you have to connect the ground with the protected earth conductor To avoid ground loops local distant ground constructions cubicles construction and machine parts have to be connected w...

Page 67: ...p B Group C Group D Group A 1 2 3 4 Group B 2 1 3 4 Group C 3 3 1 4 Group D 4 4 4 1 1 The lines may be installed in common bundles or cable trusses 2 The lines have to be installed in different bundle...

Page 68: ...ng conductor must not exceed 10 of the impedance of the screen where screened signal lines are connected between the dif ferent sections of the plant and the screening is connected to ground neutral o...

Page 69: ...ct the screen to PIN 1 of the connector In case of stationary operations it is recommended that the remove the insulation from the screened cable without cutting the screen and to attach this point to...

Page 70: ...stor using RC network Every cubicle must be provided with a power outlet for the PU These outlets must be wired to the distribution system which is also used to connect the neutral conductor for the c...

Page 71: ...ns of grounding straps connected to the body of the cubicle Cable routing Cabling divided into groups Power cables 230 400V and signal lines installed in separate channels or bunches Potential compens...

Page 72: ...Appendix HMI Appendix HB160 PPC 67S RRJ0 en 23 10 72...

Page 73: ...Content A History of changes 74 HMI Appendix HB160 PPC 67S RRJ0 en 23 10 73...

Page 74: ...Description Use in difficult operating conditions was added Chapter Industrial Security and Installation guidelines n Description Industrial security and Installation guidelines was added 23 10 Chapte...

Reviews: