RULES FOR SAFE OPERATION 

READ ALL INSTRUCTIONS 

BEFORE OPERATING 

 

When  using  the  unit,  follow  all safety  rules.  Please  read  these

 

instructions before operating the unit in order to ensure the safety of the operator and 

WARNING:

any bystanders. Please keep these instructions for later use. 

  Read the instructions carefully. Be familiar with the controls and proper use of the unit. 
  Do not operate this u

nit when tired, ill or un

der the influence of alcohol, drugs or 

medication.

  Children and teens under the age of 15 must not use the unit. Inexperienced users should 

be under supervision of trained user.   

  Before each use, thoroughly inspect Blower/Vac for loose or damaged parts. Do not use 

until adjustments or repairs are made. 

  All guards and safety attachments must be installed properly before operating the unit. 
  Inspect the area before starting the Blower/ Vac. 
  Remove all debris and hard or sharp objects such as glass, wire, etc. from surface to be 

cleaned. 

  Use the unit only in daylight or in good artificial light. 
  Keep all bystanders, especially children and pets, at least 50’ (15 m) away from the unit 

while operating. 

ELECTRICAL SAFETY WARNINGS 

  When  using  electric  gardening  appliances,  basic  safety  precautions 

should  always  be  followed  to  reduce  the  risk  of  fire,  electric  shock  and  personal 
injury. Carefully read and understand the entire operator's manual before using this 

DANGER:

Blower/Vac. Read the operating instructions and safety warnings carefully. 

  Do not use the tool if the ON/OFF switch doesn’t turn OFF the tool. 
  Since the tool is double-insulated, a 2-wire extension cord (an extension cord without a 

ground) may be used.   

  This tool is double-insulated and there are no user serviceable parts inside.   
  To reduce the risk of electrical shock, this unit has a polarized plug (one blade is wider 

than the other). This unit will fit with a polarized plug in one way only. If the plug does not 
fit fully into the unit, reverse the plug. If it still does not fit, use a cord with the correct 
connection. Do not modify the Blower/Vac in any way. 

WARNING:

  To  reduce  the  risk  of  electrical  shock,  use  only  SW-A,  SOW-A, 

STW-A, STOW-A, SJW-A, SJOW-A, SJTW-W or SJTOW-A cord types. 

MINIMUM WIRE SIZE FOR EXTENSION CORDS FOR 

120 VOLT APPLIANCES USING 0

-

12 AMPS* 

Cord length (ft.) 

25

50

100

150

Wire size (AWG)*

16

14

12

10

  The wire size (AWG) for appliances using 12 A is 16 AWG for 25’, 14 AWG for 50’ and 12 

AWG for 100’. Extensions cords of 150’ need to be gauge 10, but are not recommended. 

- 3 - 

Summary of Contents for 60-3866-8

Page 1: ...TOR S MANUAL Electric Blower Vac with Bag 60 3866 8 IMPORTANT Read safety rules and instructions carefully before operating equipment 1 For parts or service please call toll free helpline at 1 866 523...

Page 2: ...tor 120 V 60 Hz 9 A Air volume 240 CFM Air velocity Two Speeds 120 and 150 MPH Mulch ratio 10 1 Collection bag capacity 150 L Operating weight 8 Ib 3 6 kg CONTENTS OF CARTON This unit includes the fol...

Page 3: ...Y WARNINGS When using electric gardening appliances basic safety precautions should always be followed to reduce the risk of fire electric shock and personal injury Carefully read and understand the e...

Page 4: ...marked as meeting ANSI Z87 1 1989 standards Also wear ear hearing protection when operating this unit Wear a face or dust mask when operating in dusty environments Long sleeve shirts are recommended...

Page 5: ...le or pets or in the direction of windows Use extra caution when blowing debris near solid objects such as trees automobiles and walls WHILE OPERATING UNIT AS A VAC z Avoid situations that could catch...

Page 6: ...al injury make sure the unit is in the OFF position it is unplugged and the impellers have stopped before attaching or removing tubes Assemble as a blower 1 Turn off unit and unplug from electric outl...

Page 7: ...clockwise NOTE It may be necessary to remove the blower tube or vac tubes to clear a blocked tube or WARNING To prevent serious personal injury make sure the switch is in the OFF position it is unplu...

Page 8: ...the notch above the handle This prevents accidental removal of the electrical cord 2 Plug the female end of the electrical cord into the receptacle at the back of the unit STARTING STOPPING INSTRUCTIO...

Page 9: ...ny lawn and garden applications including areas such as gutters screens patios grills porches and gardens Watch out for children pets open windows or freshly washed cars and blow debris safely away Cl...

Page 10: ...ould be added to this unit Extreme care and knowledge of the system is required when servicing a double insulated unit Service should be performed by qualified service personnel only Replacement parts...

Page 11: ...age as described in clearing a blocked tube impeller Blocked impeller Clear the blockage as described in clearing a blocked tube impeller Damaged impeller Take the unit to an authorized service dealer...

Page 12: ...Cutting Line Inner Reels Starter Pulley and Starter Ropes b YARDWORKS does not extend any warranty for products sold or exported outside of the Canada YARDWORKS reserves the right to change or improv...

Page 13: ...PARTS LIST 13 30...

Page 14: ...cushion 35 3490552 2 Terminal sheath 14 PARTS LIST Item No Part No Qty Description 1 3411527 1 Front blower tube 2 3411627 1 Rear blower tube 3 3340227 1 1 Spring 4 3410727 3 1 Lock button 5 3411927 1...