Yamind CP101 User Manual Download Page 1

CP101

Summary of Contents for CP101

Page 1: ...CP101 ...

Page 2: ......

Page 3: ...SCOPE OF APPLICATION 11 CONTRINDICATION 11 ENVIRONMENT REQUIREMENT 11 TRANSPORTATION AND STORAGE CONDITIONS 12 ADDITIONAL REMARKS 12 PURITY VALUE AND FLOW FUNTIONS CHART 13 TECHNICAL PARAMETERS 14 COMPONENTS NAME AND FUNTIONS DESCRIPTION 15 CLEANING AND MAINTENANCE INSTRUCTIONS 18 WARRANTY 18 FAULT AND REPAIRING COMPARISON TABLE 19 ELECTROMAGNETIC IMMUNITY 21 ENVIRONMENT PROTECTION 23 MANUFACTURER...

Page 4: ...ons carefully on the use of this manual Before you operate the machine please make sure that you have read and understand the basic operation of this product Please pay special attention IMPORTANT SAFEGUARDS Please note that some illustrations in this manual is not exactly the same with the machine you see The humidification bottle oxygen tubes oxygen masks filters and other random components ment...

Page 5: ... 1 6m of hot sparking objects or naked sources of flame Do not smoke while your oxygen concentrator is operating or when you are near a person utilizing oxygen therapy The inappropriate use of power line and a plug may cause a fire or other dangerous electric shock burn do not use the machine with broken power line Before cleaning the machine dust in the shell must pull out the power plug to preve...

Page 6: ...ommended flow at rated oxygen concentration the outout purity will be less than 90 Do not let many people use the same set of nasal oxygen tube or oxygen mask so to avoid cross infection caused by viruses or bacteria between users We should use the required specification humidification bottle Do not replace it arbitrarily otherwise it may cause discomfort or not oxygen inhalation hazard The nasal ...

Page 7: ...the row insert board seat Do not use with other electrical appliances at the same time use the power supply socket This machine is strictly prohibited contact with oil and grease such as the need to connect to other pipelines valves connectors the use of this product the connection set before the installation should be cleaned to ensure clean and no oil grease category In the connection process pa...

Page 8: ...ed every 100 hours The Air filter is recommended to be replaced after 1000 hours of machine use Such as the use of the product environment dust or soot larger the above parts please reduce the time of cleaning or replacement In order to ensure the use of the effect the proposed early replacement of the parts The use of water can be used as a humidified bottle must be distilled water or cold water ...

Page 9: ...Please refer to CHECK PACKAGE AND PACKING LIST to test the equipped components after receive the goods and before use and then operate it as PRODUCT OPERATING PROCEDURE RELATED USE SYMBLE DESCRIPTION O OFF POWDER I ON POWDER Follow the instructions No open flame No Smoking Produating Date Safeguard Serise Number Cautions Up Put Double insulated Avoid the rain Keep dry Type BF applied part Fragile ...

Page 10: ...ing List Number Product Component Name Quantity Unit 1 Oxygen Concentrator 1 Unit 2 Humidification Bottle 1 Piece 3 Nasal Oxygen Tube 1 Piece 4 Air intake flitering foam 1 Piece 5 User Manual 1 Piece PRODUCT OPERATING PROCEDURE 1 The tie on the bottom of the machine need to be cut off before boot The machine back need to be far from the wall at least 30 cm must be the bottom of the bubble board an...

Page 11: ...o the outlet port see Figure 2 Notice The best installation place as figure 2 3 Remove the AC power line from the retaining strip confirm the sw itch in the off position Insert the plug into the indoor power outlet at this time 4 Medical oxygen concentrator with the equipment to monitor Highest Water Level Lowest Water Level Fix the humidifer by screw please take off when don t use Figure1 Figure ...

Page 12: ...it of the bottle and then put the nasal tube to the user ears insert the nasal plug in the oxygen inhalation tube and to the nostrils of the oxygen inhalation person tomake the oxygen inhalation Like Figure 3 7 When the machine is running if the alarm is sounded please check whether the power supply connection is loose or not or whether the external power supply has been interrupted 8 When oxygen ...

Page 13: ... nitrogen and oxygen molecules in the air separation oxygen retention nitrogen discharge When the power is switched on at room temperature the oxygen in the air can be separated from the air to meet the medical standard STRUCTUR This product is composed of the machine body flowmeter humidification bottle nasal oxygen tube or oxygen mask SCOPE OF APPLICATION The equipment is mainly suitable for the...

Page 14: ...under the normal temperature environment for over four hours before use it ADDITIONAL REMARKS Classification of protection against electric shock Class II Classification according to the degree of protection against electric shock Class BF Classification according to the degree of protection of the liquid into the machine IP21 Device According to the degree of safety classification used in flammab...

Page 15: ...ing Continuous working With the application of oxygen free discharge part of the protective effect of defibrillation Oxygen Concentrator is for non permanent installation equipment Altitude 0 meter to 2000 meter oxygen purity 90 2001 meter to 4000 meter 90 PURITY VALUE AND FLOW FUNTIONS CHART CP101 output pressure 0 Purity and value flow funtions chart Figure 4 Figure 4 ...

Page 16: ...t Flow purity within 10min up to the standard 90 Range of adusting flow 0 10L min adusted continously Net Weight Kg 20 5 Noise dB A 55 Dimension mm L400 W300 H540 Oxygen output pressure 60kPa 80kPa Yellow low oxygen indicator light When 72 purity 82 the yellow indicator will shin contact the supplier Make sure have the spare oxygen nearby when use it continously Red alarm indicator light When puri...

Page 17: ...en outlet Connect to the humidified bottle or nasal oxygen tube by connecting tube 2 Product nameplate serial number label product performance product serial number 3 Air intake flitering foam To prevent dirt dust fibers into the machine 4 Heat sink On the bottom of the machine the equipment can not be blocked at work 5 Straight out of the AC power cord with plug 6 Castor 4 flexible mobile machine...

Page 18: ... adjust and control the flow of output oxygen Notice Test the oxygen flow meter and make sure the knot in the regular tick mark CP101 Max flow 5L min do not let the knot over 5liter The oxygen flow is so important so do not add or down the flow just refer to the flow the doctor required Flow will be reduced if the flow meter is rotated clockwise Will eventually shut down the flow of oxygen If the ...

Page 19: ... Show Hi P High pressure alarm Show Hi Po2 cycle fault and high pressure alarm Note Machine have the following self test funtions Low purity cycle faultor purity 72 alarm low pressure alarm cycle fault and low pressure alarm High pressure alarm cycle fault and high pressure alarm When working normally fault monitoring function oxygen machine will monitor the working state of oxygen making machine ...

Page 20: ... with white vinegar with water at the ratio of 1 3 mixture of fungicides 30 minutes in the humidification bottle after the separation of the solution and then dry the wet bottle 3 Clean the Air intake flitering foam take off the cotton on the back side of the box clean it with detergent and rinse thoroughly with clear wate Dry in the air If do not dry thoroughly please don t use it This is the imp...

Page 21: ...e repair decomposition assembly without allowance from professional personnel 5 Normal damage of wearing parts and parts 6 Failure and damage caused by force majeure e g fire flood earthquake etc FAULT AND REPAIRING COMPARISON TABLE In order to avoid electric shock please do not open the shell Only authorized personnel Attached below the fault and repairing comparison table will help you analyze t...

Page 22: ...ntake flitering foam is blocked Check the Air intake flitering foam If the flitering foam is dirty wash it following the cleaning instructions on page 19 2 Exhaust is blocked Check the exhaust area make sure there is nothing restricting the unit exhaust 3 Blocked or defective nasal cannula catheter face mask or oxygen tubing Detach nasal cannula catheter or face mask If proper flow is restored cle...

Page 23: ... the clutter Check whether the Air filter is dirty if dirty please timely replace as required on page 6 3 Exhaust is blocked Check the exhaust area make sure there is nothing restricting the unit exhaust If the above remedies do not work contact your Medical provider If the machine is still not working properly please contact the product supplier or service point If there is no special description...

Page 24: ...z to 80 MHz 3 V d P V 5 3 1 d P E 5 3 1 80 MHz to 800 MHz Conducte d RF IEC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m d P E 7 1 800 MHz to 2 5 GHz Where p is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation distance in meters m b Field strengths from fixed RF transmitters as determined by an electromagnetic si...

Page 25: ...measured field strength in the location in which the CP101 OXYGEN CONCENTRATOR is used exceeds the applicable RF compliance level above the CP101 OXYGEN CONCENTRATOR should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the CP101 OXYGEN CONCENTRATOR b Over the frequency range 150 kHz to 80 MHz field ...

Page 26: ... AC Zeytinburnu İstanbul TÜRKİYE MERKEZ Sümer Mah Prof Dr Turan Güneş Cad No 57 AC Zeytinburnu İSTANBUL TEKNİK SERVİS Telsiz Mah Balıklı Kazlıçeşme Yolu Sok No 29 A Zeytinburnu İSTANBUL CİBALİ Zeyrek Mah Atatürk Bulvarı 7 G Fatih İSTANBUL SGK Cibali Binası Yanı MALTEPE Başıbüyük Mah Başıbüyük Cad No 10 A 2 Maltepe İSTANBUL KARAGÜL Molla Gürani Mah Turgut Özal Millet Cad Karagül İş Merkezi No 84 2B...

Page 27: ......

Page 28: ......