Operation Manual

Connecting the RS-232C Option

 

With the DP-6200 and the device it is being connected to both powered off, connect the DB-9 (F) 

end of the cable to the DB-9 (M) port on the back of the indicator housing.  Connect the other end 

of the cable to the serial port on the other device (i.e. - computer, printer, etc.)  To connect the DP-

6200 to a PC, use a DB-9 (F/F) straight thru cable.  Do NOT use a null modem cable.  Power on 

the DP‑6200 and configure User Parameters 03 to 08 as desired for your serial communications 

(see section VII User Parameters.)  Configure the connecting device to the same serial settings ac

-

cording to the manufacturer's instructions.  The default RS-232 settings for the DP-6200 are:

Keyword Default

Function

Description

03

001

Communication

Specified commands acceptable

04

000

Communication Data

Net weight (1 batch)

05

000

Communication Speed

9600 bps

06

000

Character Length

8 bits

07

002

Parity

Even

08

001

Stop Bit Length

2 bits

 

* * * WARNING * * *

 

RS-232 is not a hot swappable connection.  Connecting or disconnecting the serial cable while the 

DP-6200 and/or the serial device are powered on can damage the circuits of either device.  Power 

off both the DP-6200 and the serial device before connecting or disconnecting the serial cable.

III Setup

6

Summary of Contents for DP-6200

Page 1: ...MATO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604...

Page 2: ...ling the Scale Installing Batteries or AC Adaptor IV Directions for Use 7 Turning the Scale On and Off Checking the Battery Level Zero the Display Switching Units The CAL Indicator Setting the Over Un...

Page 3: ...e panel 2 Use the specified power supply and choose a suitable environment If you do not the weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrume...

Page 4: ...BRACKET FLOAT LEVEL LEVELLING LEGS PLATFORM COVER WEIGHING PLATFORM COLUMN COLUMN BRACKET STOP SCREW STOP SCREW HOLE LOCKING SCREWS FIG 1 FIG 2 FIG 3 Name and Function of Parts SERIAL NO PLATE AC ADAP...

Page 5: ...ght Gross Indicator The scale is indicating gross weight Center of Zero Indicator The scale is at gross zero CAL Indicator The scale is not sealed for legal for trade operation 6 Net Gross Key Toggles...

Page 6: ...l Consumption 0 12 W max Battery life 600 hours of continuous use with alkaline batteries Using the RS 232C option will substantially reduce battery life Operating temperature 23 F to 95 F 5 C to 35 C...

Page 7: ...cket The bubble should be in the center of the circle Adjust the trim by turning the feet in or out to lower or raise the corner of the scale the foot is on When the scale is level tighten the lock nu...

Page 8: ...section VII User Parameters Configure the connecting device to the same serial settings ac cording to the manufacturer s instructions The default RS 232 settings for the DP 6200 are Keyword Default Fu...

Page 9: ...e scale will start normally Zero the Display The scale will zero automatically when turned on If a value is displayed when the platform is empty push the ON key to zero the display The maximum zero ra...

Page 10: ...will be indicated as under 6 Press and hold the ON key and push the NET GROSS key yellow tabs This saves the lower limit and moves to the upper limit 7 Press the ON key to select the digit you want t...

Page 11: ...rrow will appear Gross Weighing 1 Begin with no load on the scale the display reading zero and the center of zero stable and gross indicators lit 2 Place the item s to weighed on the scale platform an...

Page 12: ...tors lit 2 Place an empty container on the scale platform and press the T key The weight of the container will be deducted auto matically the display will read zero and the net indicator will light 3...

Page 13: ...e excess weight from the scale platform Weight out of range low When the weighed value is a few divisions below calibrated zero this message will be displayed It is usually displayed when the platform...

Page 14: ...disturbance error This indication is occa sionally displayed due to strong static electricity and or electro magnetic disturbance Move the scale away from any sources of electromagnetic radiation mot...

Page 15: ...ing modes requires the scale to be opened and the test jumpers to be shorted to enter Test Mode System parameter 40 must be set to 000 or 002 to enable keypad entry to user parameter mode This will al...

Page 16: ...value by one T NET GROSS increase value by ten NET GROSS decrease value by one NET GROSS T decrease value by ten Example To select the metric mode as default on power up press the T key to change the...

Page 17: ...pecified commands acceptable 002 Sends zero detection 003 Sends motion detection 004 Sends continuously 04 000 Communication data 000 Net weight 1 batch 001 Net weight tare weight gross weight 1 batch...

Reviews: