14

A

B

 Move the device upward from your 

nose to the inner corner of your eyes 

and let it slide to the outer corners

 Move the device from the outer 

corner of eyes to your temple

 Move the device in a circle in the 

area between your eyebrows

 Move the device to your temple 

then move it in an upward direction

Move the device from 
above the eyebrows 
toward the hairline 
while making circles

 Move the device in an upward 

direction while making circles

 Move the device in an upward 

direction along the jawline and 
then move it downward along 
the neck

Move the device in an upward direction from 

around the mouth while making circles in the 

order 

Ⓐ→Ⓑ→Ⓒ

, and move it along the 

cheekbone

Move the device in an upward direction while 

making circles in the order 

Ⓐ→Ⓓ→Ⓔ

Move the device in an upward direction while 

making circles in the order 

Ⓐ→Ⓕ

Make five circles at the points shown as          

each time

Level

lamp

After about 70 seconds

After about 60 seconds

After about 110 seconds

After about 60 seconds

* This refers to the time during which the device is touching your skin and the touch sensor is activated. The device will not output current when it is not touching your skin.

C

B

D

A

A

D

B

C

E

F

Move the device as shown in diagrams 

 to 

 below repeatedly to perform treatment. Take each circled letter as the starting point and move the device in the directions of the arrows. 

Perform the treatment for the right side of the face as indicated below.    * In Power level, the output varies depending on the area treated.

How to move the device in Power level

Solid lighting

Flashing

OFF

When the entire face 

has been treated, the 

device will shut off 

entirely.

Eye area treatment

Face contour treatment

Smile lines treatment

Forehead treatment

Apply the included skin care product

Apply the included skin care product

Apply the included skin care product

Apply the included skin care product

When the 

standby function 

is activated

When the 

standby function 

is activated

When the 

standby function 

is activated

When the 

standby function 

is activated

 

Recommended speed for moving the device: 4 cm/second.

 

Recommended duration of use: about 10 minutes per use (over the entire face).

 

After a set period of time (approx. 5 minutes), the standby function will be activated and paused. To resume, press the Power button (       ).

 

If you want to stop the treatment during use, press the Power button (       ) for at least one second to turn off the power.

Left side of the face

Right side of the face

Approx. 

5 min.*

Approx. 

5 min.*

Summary of Contents for Bloom 6

Page 1: ...or scan with QR code with your camera phone Please carefully read User s Manual to ensure safe and proper use of the device TO ACCESS SCAN WITH YOUR CAMERA PHONE Introduction 1 Safety Precautions 1 W...

Page 2: ...to keep this User s Manual in an accessible location Make sure to include this User s Manual if you are transferring ownership of the device to another person Classifications of Precautions Symbols Re...

Page 3: ...e If you have a skin disease or atopic dermatitis If you are a hospital outpatient and are taking medication If you have a pre existing skin condition such as an allergic constitution or contact derma...

Page 4: ...the plug from the device during use Failure to comply may cause an electric shock or a fire due to a short circuit Be sure to turn off the power before pulling out the plug Do not leave the device una...

Page 5: ...to comply may cause an electric shock short circuit fire or failure of the device After using the device when the device is not in use and when cleaning it be sure to turn off the power and remove th...

Page 6: ...y level Use the device at an intensity level that suits you Make only gradual adjustments to the intensity level Failure to comply may cause an accident or an injury Check carefully that your skin is...

Page 7: ...lfunction of the device Be sure to check the plug configuration and the voltage of the power outlet before use Mandatory compliance WARNING The plug configuration and voltage may vary depending on the...

Page 8: ...nctions of Components Main Body Electrode head Power button Charging terminal Front view Back view Level button Level lamp Power level Level 3 Level 2 Level 1 AC adapter Skin care product User s Manua...

Page 9: ...out 6 minutes for the entire face for levels 1 to 3 after the current sensor touch sensor are activated and about 10 minutes for the Power level if you change the level partway through treatment the l...

Page 10: ...low Red flash Orange light Remaining battery level indicator This product can be used either cordless or by connecting it to an AC adapter Charge the battery Or connect the device to an AC adapter CA...

Page 11: ...comply may cause an accident or an injury The recommended ambient temperature is between 10 C and 40 C Wash the inner side of your arm with a soap and water then wipe dry with a towel Apply the includ...

Page 12: ...s are activated Electrode head 2 Select the level Each time the Level button is pressed levels can be adjusted Level 1 Level 2 Level 3 Power level Level 1 Level 2 You can check the treatment level fro...

Page 13: ...ays some liquid between the electrode head and the skin If there is an insufficient amount of skin care product or water the stimulation will become weaker causing skin problems If the device does not...

Page 14: ...device will not output current when it is not touching your skin Left side of the face Right side of the face After approx 30 seconds Onelongbeep Move the device in the directions of the arrows in ord...

Page 15: ...is not touching your skin C B D A A D B C E F Move the device as shown in diagrams to below repeatedly to perform treatment Take each circled letter as the starting point and move the device in the di...

Page 16: ...ishing powder Failure to comply may cause damage to the surface of the device Do not leave the device with skin care products on it When cleaning the device be sure to turn it off and disconnect the A...

Page 17: ...e device for a long period of time check to see that it is functioning normally before re starting use Failure to comply may cause an accident or a malfunction of the device If the device is malfuncti...

Page 18: ...ng it The device does not turn on The device shuts off The device only operates for a few minutes even after charging Insert the included AC adapter into the main unit page 9 Check to make sure the ca...

Page 19: ...function Press the Power button to restart Lower the level Be sure to use Level 1 on the first use Use in a position in which the entire surface of the electrode head comes in contact with your skin...

Page 20: ...mounts as guided We recommend using gel skin care products If you feel that the amount of skin care product is insufficient add more Can I use the device in the bathroom This device is not waterproof...

Page 21: ...esin and polycarbonate Electrode head PET resin and stainless steel Approx 180 g Approx W47 x D47 x H181 mm Approx 21 W Recommended environmental temperature 10 C to 40 C Battery Lithium ion battery C...

Page 22: ...ies and regions outside Japan please contact the store where you purchased your product for any inquiries Alternatively check the YA MAN GLOBAL Official Website https www ya man com en Official websit...

Page 23: ...local distributor for battery replacement Disposing of the device Follow your local government rules for proper disposal of this product This product uses a lithium ion battery Correct Disposal of thi...

Page 24: ...below to remove the battery Operation Steps Screw Cable Connector Do not cut the cable Pay attention not to damage the battery Remove the outer cover using a flat tipped object like a flatheaded scre...

Page 25: ...24...

Page 26: ...25...

Page 27: ...YJFS16PN 1 001E...

Reviews: