5
MAINTENANCE SPECIFICATIONS
SPEC
JET UNIT
Item
Unit
XL700
Jet pump:
Impeller clearance
Service limit
Impeller shaft run out
mm (in)
mm (in)
mm (in)
0.25
0.35 (0.010
0.014)
0.6 (0.024)
0.3 (0.012)
ELECTRICAL
Item
Unit
XL700
Ignition system:
Type
Ignition timing
at 1,200 rpm
at 5,500 rpm
Degree
Degree
CDI magneto
15 BTDC
21 BTDC
Stator:
Model / Manufacturer
Pulser coil resistance
(color)
Charging coil resistance
(color)
Ω
Ω
F4T31671 / MITSUBISHI
12.6
15.4 (W / R – B)
497.7
608.3 (Br / W – B)
CDI unit:
Stamped mark
Model / Manufacturer
Over revolution limit
Overheat revolution control
r / min
r / min
62T-01
F8T13175 / MITSUBISHI
7,000
7,400
3,000
3,800
Ignition coil:
Stamped mark
Model / Manufacturer
Primary winding resistance
Secondary winding resistance
Ω
k
Ω
62E-11
F6T532 / MITSUBISHI
0.078
0.106 (Or – B)
14.3
30.5 (High tension cords)
Charging system:
Type
Lighting coil resistance
(color)
Ω
Flywheel magneto
1.14
1.40 (G – G)
Rectifier regulator:
Model / Manufacturer
Regulator voltage
V
SH589-12 / SHINDENGEN
14.3
15.3
Thermo switch:
ON
OFF
C (
F)
C (
F)
76
84 (169
183)
63
77 (145
171)
Starter motor:
Model / Manufacturer
Brush length
Wear limit
Commutator under cut
Limit
Commutator diameter
Limit
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
SM13237 / MITSUBA
12.5 (0.44)
6.5 (0.26)
0.7 (0.028)
0.2 (0.008)
28.0 (1.10)
27.0 (1.06)
Fuse:
Rating
V – A
12-10