4-32
4
Compression damping force (for slow com-
pression damping)
To increase the compression damping force
and thereby harden the compression damp-
ing, turn the compression damping force ad-
justing screw in direction (a). To decrease the
compression damping force and thereby
soften the compression damping, turn the
adjusting screw in direction (b).
WARNING
EWB03500
These shock absorber assemblies contain
highly pressurized nitrogen gas. Read and
understand the following information be-
fore handling the shock absorber assem-
blies.
Do not tamper with or attempt to open
the cylinder assemblies.
Do not subject the shock absorber as-
sembly to an open flame or other high
heat source. This may cause the unit to
explode due to excessive gas pressure.
1. Compression damping force adjusting screw (for slow
compression damping)
1
(a)
(b)
Compression damping setting (for slow com-
pression damping):
Minimum (soft):
18 click(s) in direction (b)*
Standard:
12 click(s) in direction (b)*
Maximum (hard):
1 click(s) in direction (b)*
* With the adjusting screw fully turned in di-
rection (a)
U2MB7BE0.book Page 32 Thursday, March 3, 2016 11:46 AM