7-42
E
–
+
ELEC
STARTER MOTOR
6. Inspect:
• Armature coil continuity
Out of specification
→
Replace.
Armature coil continuity:
Commutator segments
1
Continuity
Segment - Laminations
2
No
continuity
Segment - Armature shaft
No continuity
Brush holder inspection
1. Measure:
• Brush length
a
Below specification
→
Replace.
Brush length:
12.5 mm (0.49 in)
Wear limit:
6.5 mm (0.26 in)
2. Check:
• Brush holder continuity
Out of specification
→
Replace.
Brush holder continuity:
Brush holder - Base
No continuity
Starter motor front cover inspection
1. Inspect:
• Starter motor front cover oil seal
Damage/wear
→
Replace the starter
motor front cover.