background image

Device features

- 12 -

 Owner’s Manual

Tio1608-D

• Switch 4 (Dante SECONDARY port mode)

This switch determines the operating mode of the 
[SECONDARY] Dante connector.

When Quick Config is used, these switches are 
disabled.

• Switches 5 and 6 (IP address mode)

These switches determine how the unit's IP address is 
set.

• Switches 7 and 8 (start up mode)

These switches determine how the unit starts up 
during start up mode. When set to "refresh" mode, 
the settings of the mixer are applied when the unit 
starts up. When set to "resume" mode, the unit 
returns to the same state as the last time it was used.

When Quick Config is used, the "normal operation" 
mode settings are disabled.

4

[PRIMARY] and [SECONDARY] Dante connectors

etherCON CAT5 connector that connects the unit to a 
Dante device, such as a NY64-D digital audio interface 
card. When DIP switch 4 is set to the daisy-chain 
connection position (i.e., up position), signals 
received on one connector are sent out via the other 
connector. When DIP switch 4 is set to the redundant 
connection position (i.e., down position), the 
[SECONDARY] connector functions as a backup and 
carries the same signals as the [PRIMARY] connector. If 
for some reason signals cannot be carried over the 
[PRIMARY] connector (for example, because the cable 
becomes damaged or disconnected, or because the 
network switch malfunctions), the unit switches to 
the [SECONDARY] connector.

5

[LINK/ACT] indicators

Indicate the status of the signals carried by the 
[PRIMARY] and [SECONDARY] connectors. If an 
indicator is flashing quickly, the corresponding 
Ethernet cable is not connected properly.

6

[1G] indicators

Indicate the connection status of the PRIMARY and 
SECONDARY connectors. If an indicator is lit, the 
corresponding connector is connected to a Gigabit 
Ethernet network.

NOTE

If switches 7 and 8 are set to the "update mode" or "diagnostic 
mode" positions, the unit will not be reset.

Switch 

position

[SECONDARY] connector operating 

mode

Daisy chain connection

Redundant connection

NOTE

When the Switch 4 is set to "Redundant connection", the 
head amp control function (

page 14

)  is only available via 

the [PRIMARY] Dante connector.

Switch 

position

IP address mode

Auto (link local)

DHCP

Static IP Auto (192.168.0.ID)

Static IP Manual
The IP address is specified from an 
external device such as R Remote V3.

Switch 

position

Start up mode

Refresh mode (normal operation)

Resume mode (normal operation)

Update mode

4

4

5 6

5 6

5 6

5 6

7 8

7 8

7 8

Diagnostic mode

NOTE

• Update mode and diagnostic mode are used when 

performing maintenance on the unit. Normally you will not 
use these modes.

• Update mode and diagnostic mode can be enabled even 

when using Quick Config. Normally you will not use these 
modes.

NOTE

• To avoid electromagnetic interference, use shielded 

twisted-pair (STP) cables that are rated at CAT5e or higher. 
Use conductive tape or comparable means to make sure 
that the metal parts of the cable plugs are electrically 
connected to the STP cable shield.

• We recommend using RJ-45 plugs that are compatible with 

Neutrik etherCON CAT5 connectors. You can also use 
cables with standard RJ-45 plugs.

• The maximum length of cable that can be used varies 

depending on the type of cable. When using CAT5e cables, 
data can be sent between devices that are connected by up 
to 100 m of cable.

Switch 

position

Start up mode

7 8

Summary of Contents for Tio1608-D

Page 1: ...l Bedienungsanleitung Mode d emploi Manual de instrucciones Manual do Proprietário Manuale di istruzioni Руководство пользователя 取 扱 説 明 書 AUDIO INTERFACE English Deutsch Français Español Português Italiano Русский 日本語 Tio1608 D I O RACK ...

Page 2: ...when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped PRÉCAUTIONS CONCER NANT LA SÉCUR...

Page 3: ...sults please contact the local retailer authorized to distribute this type of product If you can not locate the appropriate retailer please contact Yamaha Corporation of America Electronic Service Division 6600 Orangethorpe Ave Buena Park CA90620 The above statements apply ONLY to those products distrib uted by Yamaha Corporation of America or its subsidiaries In Finland Laite on liitettävä suojam...

Page 4: ... 4 Owner s Manual Tio1608 D ...

Page 5: ...ipment This symbol on the products packaging and or accompanying documents means that used electrical and electronic products should not be mixed with general household waste For proper treatment recovery and recycling of old products please take them to applicable collection points in accordance with your national legislation and the Directives 2002 96 EC By disposing of these products correctly ...

Page 6: ...ch as water seeps into the device turn off the power immediately and unplug the power cord from the AC outlet Then have the device inspected by qualified Yamaha service personnel Never insert or remove an electric plug with wet hands Hearing loss When turning on the AC power in your audio system always turn on the power amplifier LAST to avoid hearing loss and speaker damage When turning the power...

Page 7: ...ing the day in order to prevent the possibility of panel disfiguration unstable operation or damage to the internal components Do not place vinyl plastic or rubber objects on the device since this might discolor the panel When cleaning the device use a dry and soft cloth Do not use paint thinners solvents cleaning fluids or chemical impregnated wiping cloths Condensation can occur in the device du...

Page 8: ...about Dante please visit the Audinate website http www audinate com You can also find information about Dante and Dante compatible products on the Yamaha Pro Audio website http www yamahaproaudio com Precautions when rackmounting This product is designed to function in environments with a temperature of 0 to 40 C If you install this product together with multiple units of the same device or other ...

Page 9: ...efore changing the UNIT ID switch position If you move the switch while the unit is turned on the new switch position is not applied See Connection methods page 13 for information about Quick Config 7 QUICK CONFIG switch Turns Quick Config on and off When not using Quick Config this switch and the DIP switches on the rear of the unit determine the ID page 11 12 Turn the unit off before changing th...

Page 10: ...ned on the green indicator should either light or flash if the indicator is off an error has occurred 0 48V MASTER switch Turns the unit s 48 V phantom power on and off If the 48V MASTER switch is off no phantom power is supplied to the input jacks even if phantom power is turned on for individual inputs In this case the 48V indicators for individual inputs will still light even though no phantom ...

Page 11: ...IP switches Determines the unit s start up mode Make sure that the unit is turned off before adjusting the DIP switches If you adjust the switches while the unit is turned on the new switch positions are not applied The following information explains how the DIP switch positions Switch 1 and 2 unit ID These DIP switches along with the UNIT ID switch determine the unit s UNIT ID when Quick Config i...

Page 12: ...le is not connected properly 6 1G indicators Indicate the connection status of the PRIMARY and SECONDARY connectors If an indicator is lit the corresponding connector is connected to a Gigabit Ethernet network NOTE If switches 7 and 8 are set to the update mode or diagnostic mode positions the unit will not be reset Switch position SECONDARY connector operating mode Daisy chain connection Redundan...

Page 13: ...xing console or to other Tio1608 D units in a daisy chain configuration as shown below When using Quick Config the units will operate the same whether you connect the Ethernet cables to the PRIMARY or SECONDARY Dante connector When connecting 3 units 5 Turn each device on TF series mixing console procedure 6 Display the console s SYSTEM SETUP SLOT SETUP screen and confirm that Quick Config is enab...

Page 14: ...the unit s head amp just as you would adjust the console s head amp When using a CL or QL series digital mixer you can control or use the following parameters HA gain 48 V phantom power on off HPF on off HPF frequency cutoff adjustment Mute off 48 V phantom power master on off display Analog input level meter display Firmware version display Device identify Dante SYSTEM and SYNC indicator informat...

Page 15: ...l DIP switches are set to refresh mode but device that controls the Tio1608 D has not started up Start the device that will control the Tio1608 D and send the settings to the Tio1608 D Input level too low Condenser mic is connected Set the 48V MASTER switch to the on position Use the device that controls the Tio1608 D to turn on phantom power for the corresponding channel Internal head amp gain is...

Page 16: ...times MAC address setting is damaged and Dante communication is not possible Off Lit Duplicate UNIT ID was found Make sure each UNIT ID is only used once on the Dante network SYSTEM Indicators Description Possible Solution Lit Flashing The number of Dante transmit flows exceeded the limit Reduce the number of flows by for example using Dante Controller to change some of the transmit flows to multi...

Page 17: ...NC Indicators Description Possible Solution Lit or flashing Lit Device that is not Gigabit Ethernet compatible is connected To use Dante to send and receive digital audio make sure your devices are Gigabit Ethernet compatible Lit or flashing Flashing When using a redundancy network SECONDARY connector is sending receiving audio Check the connections of the network connected to the PRIMARY connecto...

Page 18: ... 18 Bedienungsanleitung Tio1608 D ...

Page 19: ...T 1 8 600Ω 4dBu 20Hz 20kHz GAIN 66dB 0 1 600Ω 4dBu 20Hz 20kHz GAIN 6dB 0 05 Input Output RL Conditions Min Typ Max Unit INPUT1 16 OUTPUT 1 8 600Ω Rs 150Ω GAIN 66dB 128 EIN dBu 62 dBu 600Ω Rs 150Ω GAIN 6dB 84 80 dBu all Inputs OUTPUT 1 8 600Ω Rs 150Ω GAINs 6dB Master fader at nominal level and all INPUT 1 16 in faders at nominal level Measured with TF5 or TF3 TF1 through Dante 70 dBu OUTPUT 1 8 600...

Page 20: ...nte manuale si applica alle ultime specifiche tecniche a partire dalla data di pubblicazione Per ottenere la versione più recente del manuale accedere al sito Web Yamaha e scaricare il file corrispondente В содержании данного руководства приведены последние на момент публикации технические характеристики Для получения последней версии руководства посетите веб сайт корпорации Yamaha и загрузите фай...

Page 21: ...Specifications Owner s Manual Tio1608 D 121 English Deutsch Français Español Português Italiano Русский 日本語 Dimensions Tio1608 D Unit mm 364 351 7 2 480 88 ...

Page 22: ......

Page 23: ...0 210 6686168 SWEDEN FINLAND ICELAND Yamaha Music Europe GmbH Germany filial Scandinavia JA Wettergrensgata 1 400 43 Göteborg Sweden Tel 46 31 89 34 00 DENMARK Yamaha Music Denmark Fillial of Yamaha Music Europe GmbH Tyskland Generatorvej 8C ST TH 2860 Søborg Denmark Tel 45 44 92 49 00 NORWAY Yamaha Music Europe GmbH Germany Norwegian Branch Grini Næringspark 1 1332 Østerås Norway Tel 47 6716 7800...

Page 24: ...Published 07 2017 CRES C0 2016 Yamaha Corporation Manual Development Group ZZ65080 http download yamaha com Yamaha Downloads http www yamahaproaudio com Yamaha Pro Audio global website ...

Reviews: