How to read the indicators
- 17 -
Owner’s Manual
Tio1608-D
English
Warnings
The indicators will light and/or flash as shown until the cause is resolved.
If the green [SYNC] indicator is unlit, the unit’s clock is unconfirmed.
If the green indicator is flashing, the unit is the clock master.
If the green indicator is lit, the unit is the clock slave and the clock is synchronized.
Information Message
The indicators will remain lit and/or flashing cyclically to report the status.
If the orange [SYNC] indicator is unlit, the unit is operating normally.
If the green [SYNC] indicator is unlit, the unit's clock is unconfirmed.
[SYNC] Indicators
Description
Possible Solution
Off
Flashing
Clock settings are incorrect.
Check the clock master and sampling
frequency settings of the Tio1608-D and
Dante Controller.
Off
Flashes 2 times
Unit not connected to Dante network.
Make sure the cables are not damaged and
that they are connected properly.
Off
Flashes 3 times
Cable wiring is wrong; cannot find other
Dante devices.
Check the wiring of the Ethernet cables.
[SYNC] Indicators
Description
Possible Solution
Lit or flashing
Lit
Device that is not Gigabit Ethernet
compatible is connected.
To use Dante to send and receive digital
audio, make sure your devices are Gigabit
Ethernet compatible.
Lit or flashing
Flashing
When using a redundancy network,
[SECONDARY] connector is sending/
receiving audio.
Check the connections of the network
connected to the [PRIMARY] connector.
Lit or flashing
Flashes 2 times
When using a redundancy network, error
was detected on the [SECONDARY]
connector.
Check the connections of the network
connected to the [SECONDARY] connector.
[SYNC] Indicators
Description
Possible Solution
Off
Lit
Synchronizing on a Dante network.
Please wait until started has completed or
until the unit has finished synchronization. It
may take up to 45 seconds for completion.
Waiting to receive setting data.
If START UP MODE is set to REFRESH on
the Tio1608-D unit, the input/output will be
muted until the unit receives setting data after
it starts up.
Flashing
Off
The unit is functioning correctly as the word
clock master.
The unit is operating as the word clock
master.
Lit
Off
The unit is functioning correctly as the word
clock slave.
The unit is operating as the clock slave and
the clock is synchronized.