This product contains chemicals known to the State of California to cause cancer, or birth defects or other reproductive
harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REASON
WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or
expose eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
1. Critical Components Information
Components having special characteristics are marked
⚠
and
must be replaced with parts having specifications equal to those
originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
• Meter impedance should be equivalent to 1500 ohms shunted
by 0.15 μF.
All of the P.C.B.s installed in this unit and solder joints are soldered using the lead free solder.
Among some types of lead free solder currently available, it is recommended to use one of the following types for the
repair work.
• Sn + Ag + Cu (tin + copper)
• Sn + Cu (tin + copper)
• Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
As the melting point temperature of the lead free solder is about 30°C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.
■
TO SERVICE PERSONNEL
• Leakage current must not exceed 0.5mA.
• Be sure to test for leakage with the AC plug in both polarities.
WARNING: CHEMICAL CONTENT NOTICE!
About lead free solder
For U model
“CAUTION”
“F1501: FOR CONTINUED PROTECTION AGAINST RISK OF FIRE, REPLACE ONLY WITH SAME TYPE 6A,
125V FUSE.”
For C model
CAUTION
F1501: REPLACE WITH SAME TYPE 6A, 125V FUSE.
ATTENTION
F1501: UTILISER UN FUSIBLE DE RECHANGE DE MÉME TYPE DE 6A, 125V.
WALL
OUTLET
EQUIPMENT
UNDER TEST
AC LEAKAGE
TESTER OR
EQUIVALENT
INSULATING
TABLE
2
RX-V367/HTR-3063
RX-V367/HTR-3063
Summary of Contents for RX-V367
Page 4: ...4 RX V367 HTR 3063 RX V367 HTR 3063 HTR 3063 U C T models HTR 3063 R K A G F L models...
Page 6: ...6 RX V367 HTR 3063 RX V367 HTR 3063 RX V367 T model RX V367 K model RX V367 A model...
Page 7: ...7 RX V367 HTR 3063 RX V367 HTR 3063 RX V367 B G F models RX V367 L model HTR 3063 U model...
Page 8: ...8 RX V367 HTR 3063 RX V367 HTR 3063 HTR 3063 T model HTR 3063 C model HTR 3063 R model...
Page 9: ...9 RX V367 HTR 3063 RX V367 HTR 3063 HTR 3063 K model HTR 3063 A model HTR 3063 G E F models...
Page 10: ...10 RX V367 HTR 3063 RX V367 HTR 3063 HTR 3063 L model...
Page 102: ...ADVANCED SETUP U C models RX V367 HTR 3063 103...
Page 104: ...105 RX V367 HTR 3063 RX V367 HTR 3063 MEMO...
Page 105: ...RX V367 HTR 3063...