TEST PROGRAM
1 Preparation
Use an AC adaptor PA-5D or PA-150.
Following items are required for testing. (Input impedance of measuring instrument is more than 1 M
Ω
)
• Level meter (with JIS-C Filter)
• Frequency counter, which can detect thousandth value or more.
• MIDI cable
• Foot pedal (FC3), Foot switch (FC4 or FC5)
Set the [MASTER VOLUME] to the maximum level and leave the pedals turned off.
Connect a measuring plug (stereo plug) to the [PHONES] jack. (33
Ω
load)
2
To enter Test Program
Turn on the power with [C#2], [F2] and [G#2] keys pressed and held simultaneously. (Fig. 1)
Once the Test Program is started properly, the sine wave of A3 sounds. To stop the sound, press any key.
3
To proceed the test
Test items are listed in Table 1.
Press the corresponding key to select and execute each test. (See Fig. 2)
To enter the test item select mode after completing each test item, press the [DEMO/SONG] button or the lowest key.
4 Test
result
Each test result is indicated by the sound.
When the test result is OK, the sine wave of C4 sounds.
When the test result is NG, the sine wave of C2 sounds.