5-8
3mm
95
_
C
82”1.5
_
C
THERMOSTAT
COOL
*****************************************************
*****************************************************
NOTE:
EB502010
INSPECTION
1. Inspect:
D
Thermostatic valve
Valve does not open at 80.5
83.5
_
C
Replace.
Inspection steps:
D
Suspend the thermostatic valve in a vessel.
D
Place a reliable thermometer in water.
D
Observe the thermometer, while continually
stirring the water.
1 Thermostatic valve
2 Vessel
3 Thermometer
4 Water
A CLOSE
B OPEN
The thermostatic valve is sealed and its setting
requires specialized work. If its accuracy is in
doubt, replace it. A faulty unit could cause seri-
ous overheating or over-cooling.
2. Inspect:
D
Thermostatic cover
Cracks / damage
Replace.
YP******
INSTALLATION
1. Install:
D
Thermostatic valve
1
D
Thermostatic cover