PROTECTION OPERATION CHECK FUNCTION
1. Turn the POWER switch ON while pressing the TUNER and PRESET
STATION No.8 keys simultaneously.The protection operation mode and
microprocessor AD input value are displayed for 3 seconds.
Example : PRT-DC
[AD value]
PRT-I
[PRT-DC] indicates detection of an abnormal DC value from the amplifier.
[PRT-I] indicates detection of an abnormal overcurrent from the amplifier.
[PRT-NON] indicates no detection.
11
Type of protection
Detection of an abnormal
amplifier DC
Normal
(AD value)
128 - 255
Abnormal
(AD value)
0 - 127
Press any key, and the display will be canceled.
When the PRESET STATION No. 8 key is pressed during the above dis-
play, the input data are retained till they are cleared.
(“PRT-NON” appears on display when the data are cleared.)
2. Turn the POWER switch ON while pressing the TUNER and the PRESET
STATION No. 7 keys simultaneously, and the input value for detection of an
abnormal amplifier DC will be displayed.
Example : P - [01]
D - [AD value]
[P- XX] is meaningless and therfore should be ignored.
[DC- ] indicates detection of an abnormal amplifier DC.