Trouble Recovery
113
5. Disconnect the water detection switch
coupler.
NOTICE:
Be careful not to get
any water on the water detection
switch coupler, otherwise a malfunc-
tion could occur.
[ECM01950]
6. Remove the bolts to remove the cover.
7. Unscrew the filter cup from the filter
housing.
NOTICE:
Be careful not to
twist the water detection switch lead
when unscrewing the filter cup.
[ECM01960]
8. Drain the water in the filter cup by soak-
ing it up with a rag.
9. Firmly screw the filter cup onto the filter
housing.
NOTICE:
Be careful not to
twist the water detection switch lead
when screwing the filter cup onto the
filter housing.
[ECM01970]
10. Install the cover, and tighten the bolts.
1. Water detection switch coupler
ZMU05892
ZMU05894
1
1. Filter cup
2. Water detection switch lead
ZMU05895
ZMU05896
1
2
6AW-9-77-1E0.book 113 ページ 2010年3月16日 火曜日 午後6時8分