10. AD DATA CHECK/FAN TEST
This menu is used to display the A/D conversion value of
the terminals which detects panel keys of the main unit
and protection functions in % using the sub-menu (5V as
100%). During signal processing, the condition before
execution is maintained.
When K0/K1 menu is selected, keys become non-
operable due to detection of the values of all keys.
However, it is possible to advance to the next sub-menu
by pressing the " " key on the remote control unit.
* The figures in the diagram are given as reference only.
STATION
FM FACTORY PRESET DATA (MHz)
PAGE NO.
U, C
R, A, B, G
J
1
87.5
87.50
76.0
2
90.1
90.10
83.0
3
95.1
95.10
84.0
A/C/E
4
98.1
98.10
86.0
5
107.9
108.00
90.0
6
88.1
88.10
78.0
7
106.1
106.10
88.0
8
107.9
108.00
82.1
STATION
AM FACTORY PRESET DATA (kHz)
PAGE NO.
U, C, R
A, B, G
J
1
630
630
630
2
1080
1080
1080
3
1440
1440
1440
B/D
4
530
531
531
5
1710
1611
1611
6
900
900
900
7
1350
1350
1350
8
1400
1404
1404
•
PRESET STATIONS /
プリセット局
10. AD DATA CHECK/FAN TEST
本体パネルキー、プロテクションなどを検出している端子
のA / D 変換の値を、サブメニューで% 表示します(5 V
100%)。信号処理は実行前の状態を維持します。
K0/K1のメニューにすると、全キーの値を検出するため
キー操作はできなくなりますが、リモコンの
キーを押
すことにより、次のサブメニューに進めることができま
す。
※図中の数値は参考例です。
Display
K0
K1
0
INPUT MODE
10
VOLUME –
19
29
DSP
40
DSP
50
INPUT
60
INPUT
DISC DIRECT
69
STEREO
PROGRESSIVE
100
–
–
[Table 1]
K0/K1
(Panel key of main unit)
A/D of the key fails to function properly when the standard
value is deviated. In this case, check the constant of
partial pressure resistor, solder condition, etc. Refer to
table 1.
K0/K1
(本体パネルキー)
キーのA/Dは基準値から外れると、正常な動きをしませ
ん。Table 1をご覧になり、各キーの分圧抵抗の定数、ハン
ダ不良等の確認をしてください。
PS
(プロテクションの検出)
電源電圧プロテクションの値(正常値044〜070)
※ PSは正常値を外れるとプロテクションが働き、電源オ
フされます。
PS
(protection detection)
Power supply voltage protection value (Normal value: 044
to 070)
* If PS is out of the normal value range, the protection
function works to turn off the power within 1 second.