DVR-S100/NX-SW100
19
DVR-S100/NX-SW100
POWER AMP (3) P. C. B.
SYSTEM CONNECTOR
+
–
Set to 10V
+10Vに設定する
DC Power Supply /
DC電源
① ② ③ ④
⑫
⑥ ⑦ ⑧
⑨ ⑩ ⑪
⑬
⑤
When checking the P.C.B.:
The power to the SW-S100 cannot be turned on
independently. Connect the DVR-S100 or an external DC
power source and use it to turn on the power.
1. When using the DVR-S100
a. Using the system connection cable (DIN 13P) supplied
with the unit, connect the system connector terminal of
the DVR-S100 and that of the SW-S100.
b. Connect the power cords of the DVR-S100 and SW-
S100 to the service outlet.
c. Press the STANDBY/ON button of the DVR-S100.
2. When using the external DC power source
a. Prepare a DC power source and set the output voltage
to 10V in advance. (Fig. 14)
b. Connect pins No. 5, 10 and 13 of the system connector
terminal of the SW-S100 and the (+) output terminal of
the DC power source with a cable. (Fig. 14)
c. Connect the pin No.7 of the system connector terminal
of the SW-S100 and the (-) output terminal of the DC
power source with a cable. (Fig. 14)
d. Connect the power cords of the SW-S100 and the DC
power source to the service outlet.
e. Turn on the power switch of the DC power source.
P.C.B.チェックをする場合には
SW-S100は単独で電源を投入することができません。
DVR-S100または外部DC電源を接続して、それにより電
源を投入します。
1. DVR-S100を使用する場合
a. DVR-S100のシステムコネクター端子とSW-S100のシ
ステムコネクター端子を、付属のシステム接続ケーブル
(DIN 13P)で接続します。
b. DVR-S100およびSW-S100の電源コードを、電源コン
セントに接続します。
c. DVR-S100のSTANDBY/ONボタンを押します。
2. 外部DC電源を使用する場合
a. DC電源を用意し、あらかじめ出力電圧を10Vに設定し
ます。(Fig. 14)
b. SW-S100のシステムコネクター端子5、10、13ピン
と、DC電源+出力端子をケーブルで接続します。(Fig.
14)
c. SW-S100ののシステムコネクター端子7ピンと、DC電
源-出力端子をケーブルで接続します。(Fig. 14)
d. SW-S100およびDC電源の電源コードを、電源コンセン
トに接続します。
e. DC電源の電源SWをONします。
Fig. 14