DTXTREME IIS
68
■
ERROR MESSAGES
MIDI buffer memory has become full by receiving too much
MIDI data at a time via MIDI IN. Reduce the amount of data
(data transfer rate) or increase the interval between each
transfer on the sending device.
An error has occurred while MIDI data was being received.
Check if the MIDI cable is properly connected and if the
MIDI data is appropriate.
This is displayed when all settings are initialized. The backup
battery may be used up. In this case, it has to be replaced.
Before replacement, save the necessary data to the memory
Checksum of the received bulk data is incorrect. Check if the
data is not corrupted and appropriate for the DTXTREME
IIs, and then retry.
Received bulk data contains illegal data. Check if the data is
not corrupted and appropriate for the DTXTREME IIs, and
then retry.
This message will be shown if you attempt an operation while
the internal sequencer is running. Stop the sequencer and
retry.
This message will be shown if you attempt recording to
operation to the track that contains data. Retry recording to
an empty track.
User memory has become full. Save necessary user data to the
memory card and clear unnecessary data to release the
memory.
This message will be shown if you attempt saving onto a
write-protected memory card. Cancel write-protection of the
memory card and retry.
ERROR : MIDI input buffer full
push [ENTER]
ERROR : MIDI data error
push [ENTER]
WARNING: All data initialized
push [ENTER]
card etc.
This is displayed when the backup battey voltage is low. If
power is turned off, the user data may be lost, so save the
necessary data to the memory card etc.
WARNING : Batteryvoltage is low
push [ENTER]
ERROR : MIDI check sum error
push [ENTER]
ERROR : MIDI Illegal data
push [ENTER]
ERROR : Sequencer is Running
push [ENTER]
ERROR : Sequence data is not empty
push [ENTER]
ERROR : Memoryfull
push [ENTER]
ERROR : Card is write protected
push [ENTER]
An error has occurred while the DTXTREM IIs was reading
or writing a memory card. First re-format the memory card
and retry. If the message still appears when you attempt
reading writing on the re-formatted card, that memory card
may be broken. Replace the memory card. In any case, the
data stored on the troubled card may be corrupted.
The DTXTREME IIs cannot recognize the specified file (file
format). Check if the file is suitable for the DTXTREME IIs
and is not corrupted.
This message will be shown if you attempt to load a song
from the memory card or by receiving bulk data when a preset
song is selected (in Drum Kit Play mode). First select a user
song and then retry loading a song.
This message will be shown if you attempt to load a song
from the memory card or by receiving bulk data when a card
song is selected (in Drum Kit Play mode). First select a card
song and then retry loading a song.
You attempted loading a MIDI file created in the SMF Type 1
format. Load the MIDI file after saving as a Type 0 file using
an external sequencer.
You attempted to delete a volume (directory) that contains a
file. First delete all files in the volume, then delete it.
You attempted to rename a file with a duplicate name.
Specify a unique file name
ERROR : Card read/write error
push [ENTER]
ERROR : File is unknown format
push [ENTER]
ERROR : Can't edit preset song
push [ENTER]
ERROR : Can't edit card song
push [ENTER]
ERROR : Can't playSMF Ty
pe1
push [ENTER]
ERROR : Volume is not empty
push [ENTER]
ERROR : File alreadyexists
push [ENTER]
Summary of Contents for DTXT2S
Page 20: ...DTXTREME IIS 20 DM Circuit Board DMシート B B ...
Page 21: ...21 DTXTREME IIS Pattern side パターン側 THRU IN OUT MIDI B B ENA 908610 0 ...
Page 24: ...DTXTREME IIS 24 PN Circuit Board PNシート D D ...
Page 25: ...25 DTXTREME IIS Pattern side パターン側 D D ENA 908630 1 ...
Page 28: ...DTXTREME IIS 28 JK Circuit Board JKシート F F ...
Page 29: ...29 DTXTREME IIS Pattern side パターン側 F F ENA 908620 1 ...
Page 70: ...DTXTREME IIS 70 MIDI IMPLEMENTATION CHART MIDI インプリメンテーションチャート ...