II-44
Key Sensor Calibration One Key Correction
After performing the key Sensor Calibration in maintenance mode, or if there is unevenness in the volume of
the keys and after verifying the state in sensor test mode you performed Key Sensor Calibration but there
was no improvement, you can use the One Key Correction function to manually correct the K1 position in
order to balance the note response.
Content
Operation
Start-up
16C+18D+20E+Power ON
Select key
Play the note that you wish to correct
Waiting for triple continuous stroke
correction for corresponding key
Collection
*Press 1A or 88C to compensate
*Correction
When 1A is pressed
K1 position is raised : distance
between points is broadened : vol-
ume for identical playing strength is
fall
When 88key is pressed
K1 position is lowered : distance
between points is tightened : volume
for identical playing strength is raised
Each time 1A or 88C is pressed, the
point will rise or fall 0.2 mm.
To adjust 1A or 88C, use 2A# and
86A#.
Enter the Sensor
Test Mode
Press the damper pedal
Verify K1-K4
Waiting for correction
Press the damper pedal
Confirm correction
Press the soft pedal
76C Triple or four continuous stroke
*Do not power off the unit before these
sounds are heard.
End
Power off
Summary of Contents for disklavier MX-100A
Page 1: ...HYBRID PIANO PRODUCT HANDBOOK FOR THE PIANO TECHNICIAN MHB19 00 08 CR Printed in Japan...
Page 6: ......
Page 7: ...I 1 Part I Product Description...
Page 8: ...I 0...
Page 50: ...I 42...
Page 51: ...II 1 Part II Servicing...
Page 52: ...II 0...
Page 105: ...II 53...
Page 116: ......