ELEC
IMMOBILIZER SYSTEM
58
1. Check that the immobilizer system indicator light is flashing. It indicates the “standby mode”. To initiate
the standby mode, turn “OFF” the main switch and then it will be the standby mode when it passes 30
seconds. After 24 hours have passed, the indicator light stop flashing and the standby mode ends.
2. After the main switch is turned “ON” with the code re-registering key, before 5 seconds elapses, turn
“OFF” the main switch and then turn “ON” the main switch with the standard key (the first new key) that
you want to register.
3. It enters the key registration mode and the two standard key codes that have been stored in the mem-
ory are erased and the first new standard key code will be registered. At this time, the indicator light
rapidly blinks (“OFF” for 0.5 sec. and “ON” for 0.5 sec.).
4. In the condition as mentioned above (while the indicator light continues rapid flashing), after the main
switch is turned “ON” with the first new standard key, turn “OFF” the main switch before 5 seconds
elapses, and then turn “ON” the main switch with the standard key that you want to register (which is
the second new key or the standard key remained in hand).
5. When the registration is finished, the indicator light goes off.
6. Check that the engine can be started with the two registered standard keys.
NOTE:
The flashing stops when 5 seconds elapses and the registration mode is finished. In this case, the seccond stan-
dard key cannot be registered and only the first standard key is registered.
Voiding the standard key code:
If you lose one standard key that you used and you want to make the lost standard key unable to be used
anymore, re-register another standard key. To re-register, refer to “Standard key registration”.
This re-registration disables the lost standard key because its key code has been changed.