ELEC
8-15
61U5H11
Electrical system
2.
Check the brush holder assembly for
continuity. Replace the brush holder if not
shown as below chart.
Checking the starter motor operation
1.
Check the operation of the starter motor
after installing it onto the power unit.
Checking the choke solenoid
1.
Disconnect the choke solenoid leads.
2.
Connect the digital circuit tester to the
choke solenoid leads.
3.
Measure the resistance of the choke
solenoid. Replace the choke solenoid if
out of specification.
4.
Check the armature for continuity.
Replace the armature if not shown as
below chart.
Checking the brush
1.
Measure the brush length
a
. Replace
the brush assembly if below specification
limit.
6G480256
c
d
e
Armature continuity
Commutator segments
c
Continuity
Segment – Armature core
d
No continuity
Segment – Armature shaft
e
No continuity
Standard length:
17.0 mm (0.67 in)
Wear limit
a
:
10.0 mm (0.39 in)
6G480270
2
1
6G480280
Brush continuity:
Brush
1
– Brush
2
No continuity
Choke solenoid resistance:
3.4–4.0
Ω
61U5H11_08 05.10.7 3:02 PM Page 16